Emergency Placed Percutaneous Nephrostomy Catheter Provides Safe and Effective Access for Future Percutaneous Nephrolithotomy Operation

Author:

ŞEKER Kamil Gökhan1ORCID,ARIKAN Yusuf2ORCID,ÖZLÜ Deniz Noyan3ORCID,AYTEN Ali4ORCID,ERBAHÇECİ SALIK Aysun4ORCID,GÜNER Ekrem4ORCID

Affiliation:

1. Liv Hospital Vadistanbul

2. UNIVERSITY OF HEALTH SCIENCES, İZMİR TEPECİK HEALTH RESEARCH CENTER

3. Bitlis Devlet Hastanesi

4. UNIVERSITY OF HEALTH SCIENCES, İSTANBUL BAKIRKÖY DR. SADİ KONUK TRAINING RESEARCH CENTER

Abstract

Objective: It was aimed to investigate the feasibility of the percutaneous nephrostomy (PCN) catheter placed in an emergency in the future percutaneous nephrolithotomy (PNL) operation. Material and Methods: Patients who underwent PCN catheter insertion by an interventional radiologist under emergency situations prior to PNL surgery between January 2013 and December 2018 were included in the study. Demographic characteristics, indication for PCN insertion, stone characteristics, pre- and post-operative laboratory values, intra-operative data, usability/non-usability of PCN catheter for renal access, post-operative data and complications were recorded. Results: A total of 32 patients were included in the study. (PCN usable: 21, unusable: 11). Indications for catheter insertion were obstruction in 26 (81.25%) patients and urinary tract infection in 6 (18.75%) patients. Renal access was achieved in 21 (65.62%) patients by using the PCN catheter tract during PNL. The most common PCN access was used in the inferior pole. In 11 (34.37 %) patients, the PCN tract was not usable for access. In patients in whom PCN was unusable due to an unsuitable calyx for access, the most common new access site was the inferior calyx in 6 patients, the superior calyx in 3 patients and the middle calyx in 2 patients. There was no statistically significant difference between the two groups in which the PCN catheter was usable and unusable for PNL access (p>0.05), except for the mean length of hospital stay (p=0.039). Conclusions: PCN catheters inserted prior to PNL surgery can be used effectively and safely for renal access during surgery. However, in emergency cases, it is important that the PCN catheter is inserted through the appropriate calyx in patients undergoing future surgery.

Publisher

Endouroloji Dernegi

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3