Validation of Cartilage Thickness Calculations Using Indentation Analysis

Author:

Koff Matthew F.1,Chong Le Roy2,Virtue Patrick3,Chen Dan4,Wang Xioanan4,Wright Timothy4,Potter Hollis G.1

Affiliation:

1. Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY 10021

2. Department of Diagnostic Radiology, Changi General Hospital, Singapore 529889, Singapore

3. GE Healthcare, Waukesha, WI 53188

4. Department of Biomechanics, Hospital for Special Surgery, New York, NY 10021

Abstract

Different methods have been used to cross-validate cartilage thickness measurements from magnetic resonance images (MRIs); however, a majority of these methods rely on interpolated data points, regional mean and/or maximal thickness, or surface mean thickness for data analysis. Furthermore, the accuracy of MRI cartilage thickness measurements from commercially available software packages has not necessarily been validated and may lead to an under- or overestimation of cartilage thickness. The goal of this study was to perform a matching point-to-point validation of indirect cartilage thickness calculations using a magnetic resonance (MR) image data set with direct cartilage thickness measurements using biomechanical indentation testing at the same anatomical locations. Seven bovine distal femoral condyles were prepared and a novel phantom filled with dilute gadolinium solution was rigidly attached to each specimen. High resolution MR images were acquired, and thickness indentation analysis of the cartilage was performed immediately after scanning. Segmentation of the MR data and cartilage thickness calculation was performed using semi-automated software. Registration of MR and indentation data was performed using the fluid filled phantom. The inter- and intra-examiner differences of the measurements were also determined. A total of 105 paired MRI-indentation thickness data points were analyzed, and a significant correlation between them was found (r=0.88, p<0.0001). The mean difference (±std. dev.) between measurement techniques was 0.00±0.23 mm, with Bland–Altman limits of agreement of 0.45 mm and −0.46 mm. The intra- and inter-examiner measurement differences were 0.03±0.22 mm and 0.05±0.24 mm, respectively. This study validated cartilage thickness measurements from MR images with thickness measurements from indentation by using a novel phantom to register the image-based and laboratory-based data sets. The accuracy of the measurements was comparable to previous cartilage thickness validation studies in literature. The results of this study will aid in validating a tool for clinical evaluation of in-vivo cartilage thickness.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference37 articles.

1. Quantitative MRI of Cartilage and Bone: Degenerative Changes in Osteoarthritis;Eckstein;NMR Biomed.

2. Prevalence of Disabilities and Associated Health Conditions Among Adults—United States, 1999;Centers for Disease Control and Prevention (CDC);MMWR Morb Mortal Wkly Rep.

3. Cartilage Interstitial Fluid Load Support in Unconfined Compression;Park;J. Biomech.

4. Magnetic Resonance Imaging of Articular Cartilage in the Knee. An Evaluation With Use of Fast-Spin-Echo Imaging;Potter;J. Bone Jt. Surg., Am. Vol.

5. Cartilage MRI T2 Relaxation Time Mapping: Overview and Applications;Mosher;Semin. Musculoskelet. Radiol.

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3