Previously Unrecognized Source of Error in the Change in Maximum Total Point Motion to Determine Continuous Migration of Unstable Tibial Baseplates

Author:

Niesen Abigail E.1,Hull Maury L.2

Affiliation:

1. Department of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA 95616

2. Department of Biomedical Engineering, University of California Davis, One Shields Avenue, Davis, CA 95616; Department of Mechanical Engineering, University of California Davis, One Shields Avenue, Davis, CA 95616; Department of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento, CA 95817

Abstract

Abstract In radiostereometric analysis (RSA), continuous migration denoted as ΔMTPM is the difference between maximum total point motion (MTPM) at 2 years relative to time zero and MTPM at 1 year relative to time zero. Continuous migration has been used to diagnose tibial baseplates as stable versus unstable when compared to a specified stability limit (i.e., value of ΔMTPM). If the same point experiences MTPM at 2 years and at 1 year (usually the case for marker-based RSA), then an implicit assumption is that the migration path between 2 years and 1 year is the same as the path between 1 year and time zero. This article uses vector analysis to demonstrate a source of error in ΔMTPM not previously recognized and estimates the magnitude of error based on the interplay of independent variables which affect the error. The two independent variables which affect the error are the angle between the two migration vectors (i.e., MTPM between time zero and 2 years and MTPM between time zero and 1 year) and the difference in magnitude of the two vectors. The relative error increased in an absolute sense as the angle between the vectors increased and decreased for larger differences in the magnitudes of the two vectors. For magnitude ratios ranging from 1.25 to 2, relative errors ranged from –21% to –3% at 10 deg and from –78% to –42% at 60 deg, respectively. Knowledge of these errors highlights a limitation in the use of ΔMTPM not previously recognized.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference20 articles.

1. Analysis of Total Knee Arthroplasty Revision Causes;BMC Musculoskelet. Disord.,2018

2. Sixth American Joint Replacement Registry Annual Report on Hip and Knee Arthroplasty Data;AAOS,2019

3. Austrailian Orthopaedic Association National Joint Replacement Registry: Hip, Knee & Shoulder Arthroplasty Annual Report;AOANJRR,,2020

4. National Joint Registry for England, Wales, Northern Ireland, and the Isle Of Man. 17th Annual Report 2020;NJR,2020

5. RSA-Tested TKA Implants on Average Have Lower Mean 10-Year Revision Rates Than non-RSA-Tested Designs;Clin. Orthop. Relat. Res.,2020

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3