Novel Design of a Three-Dimensional Printed Umbilical Cord Clamp: A Proof of Concept Study

Author:

Mammadov Betul1,Vural Gulsen2,Aytac Ersin3,Mammadov Emil45

Affiliation:

1. Mem. ASME Department of Midwifery, Health Sciences Faculty, Near East University, Near East Boulevard, Nicosia 99138, Cyprus e-mails: ;

2. Mem. ASME Department of Obstetric and Gynecologic Nursing, Nursing Faculty, Near East University, Near East Boulevard, Nicosia 99138, Cyprus e-mail:

3. Mem. ASME NEU3D Laboratories, Research Center of Experimental Health Sciences, Near East University, Near East Boulevard, Nicosia 99138, Cyprus, e-mail:

4. Mem. ASME NEU3D Laboratories, Research Center of Experimental Health Sciences, Near East University, Near East Boulevard, Nicosia 99138, Cyprus;

5. Department of Pediatric Surgery, Medical Faculty, Near East University, Near East Boulevard, Nicosia 99138, Cyprus e-mail:

Abstract

Parents frequently report complaints regarding the excessive size of the clamp that create concerns of hooking to the clothes and inducing premature separation of the dried cord. We aimed to design three-dimensional (3D) print and test a novel umbilical clamp which would be smaller, more ergonomic, and would look more appealing to the parents. After the design and 3D printing process, the clamps were tested for fluid leak on fresh umbilical cord specimens. The umbilical vein was cannulated with a 4F feeding tube which was attached to the saline infusion bag inserted in a pressure infusion cuff. The compressed cord width was measured, and the cuff was inflated to 100 mmHg and 200 mmHg. Umbilical cord specimens of 152 patients were included in the main study. The mean umbilical cord diameter (UCD) was 11.1 ± 3.5 mm (range: 4.5–23.3 mm). The compressed cord width mean value after clamping with the novel design clamp was 17.3 ± 2.3 mm compared to the 23.5 ± 3.5 mm with the conventional clamp and this difference was statistically significant (p < 0.001). All of the novel clamps safely and efficiently clamped the umbilical cords without any fluid leak. The novel design umbilical cord clamp is a safe and efficient tool being able to clamp a wide range of umbilical cords. However, a prospective randomized trial on human subjects, safety-efficacy tests by independent healthcare providers, and patient satisfaction surveys are mandatory for the further approval of our claims.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference16 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370