Affiliation:
1. Forschungszentrum Karlsruhe, Karlsruhe, Germany
Abstract
This paper presents preliminary experimental results of measuring velocity fields of a transparent liquid flow in a closed circuit, through a 100 μm, 200 μm and 500 μm depth flat cell with and without included 200 μm × 200 μm heat exchanger microchannel elements. A microscopic particle image velocimetry system has been developed which consists of a 5 ns pulsed Nd:YAG laser, an epi-fluorescent microscope and a cooled interline transfer CCD camera to record high-resolution 0.7 μm diameter fluorescent particle image fields. The development of the optical micro-flow measuring instrument for the present application took into consideration the fact that the test object is aimed to be exposed to pressures up to 0.6 MPa leading to flow velocities up to 15 m/s, as well as temperatures up to 100°C. Particle fouling phenomenon proved to be the main difficulty in performing velocity field measurements in microchannels and techniques to avoid or limit it are proposed.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献