Cable Tension Optimization for an Epicardial Parallel Wire Robot

Author:

Ladak Aman1,Hajjar Roger J.2,Murali Srinivas3,Michalek Jeremy J.456,Riviere Cameron N.7

Affiliation:

1. Department of Mechanical Engineering, Carnegie Mellon University , 5000 Forbes Ave, Pittsburgh, PA 15213

2. Ring Therapeutics, 620 Memorial Drive , Cambridge, MA 02139

3. Department of Cardiovascular Medicine, Allegheny Health Network , 320 East North Avenue, Pittsburgh, PA 15212

4. Department of Engineering and Public Policy, Carnegie Mellon University , 5000 Forbes Ave, Pittsburgh, PA 15213 ; , 5000 Forbes Ave, Pittsburgh, PA 15213 ; , 5000 Forbes Ave, Pittsburgh, PA 15213

5. Department of Mechanical Engineering, Carnegie Mellon University , 5000 Forbes Ave, Pittsburgh, PA 15213 ; , 5000 Forbes Ave, Pittsburgh, PA 15213 ; , 5000 Forbes Ave, Pittsburgh, PA 15213

6. Department of Civil and Environmental Engineering, Carnegie Mellon University , 5000 Forbes Ave, Pittsburgh, PA 15213 ; , 5000 Forbes Ave, Pittsburgh, PA 15213 ; , 5000 Forbes Ave, Pittsburgh, PA 15213

7. The Robotics Institute, Carnegie Mellon University , 5000 Forbes Ave, Pittsburgh, PA 15213

Abstract

AbstractHeartPrinter is a novel under-constrained 3-cable parallel wire robot designed for minimally invasive epicardial interventions. The robot adheres to the beating heart using vacuum suction at its anchor points, with a central injector head that operates within the triangular workspace formed by the anchors, and is actuated by cables for multipoint direct gene therapy injections. Minimizing cable tensions can reduce forces on the heart at the anchor points while supporting rapid delivery of accurate injections and minimizing procedure time, risk of damage to the robot, and strain to the heart. However, cable tensions must be sufficient to hold the injector head's position as the heart moves and to prevent excessive cable slack. We pose a linear optimization problem to minimize the sum of cable tension magnitudes for HeartPrinter while ensuring the injector head is held in static equilibrium and the tensions are constrained within a feasible range. We use Karush-Kuhn-Tucker optimality conditions to derive conditional algebraic expressions for optimal cable tensions as a function of injector head position and workspace geometry, and we identify regions of injector head positions where particular combinations of cable tensions are optimally at minimum allowable tensions. The approach can rapidly solve for the minimum set of cable tensions for any robot workspace geometry and injector head position and determine whether an injection site is attainable.

Funder

Carnegie Mellon University

National Heart, Lung, and Blood Institute

National Institutes of Health

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3