Performance Analysis of a Cardiac Assist Device in Counterpulsation

Author:

Chesler N. C.1,Kamm R. D.1

Affiliation:

1. Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139

Abstract

Performance of a cardiac assist device pumping chamber in counterpulsation was evaluated using numerical simulations of the unsteady, three-dimensional flow inside the chamber and an analytical model of the force required to eject and fill the chamber. The wall shear stress within the device was similarly computed and modeled. The analytical model was scaled to match the numerical results and then used to predict performance at physiological operating conditions. According to these models for a stroke volume of 70 ml, between 0.4 and 1.0 W is required for counterpulsation at a frequency of 1.33 Hz against a restorative spring, depending on the spring constant chosen. The power and the maximum force calculated are within the ranges a trained skeletal muscle is capable of providing. Shear stress predictions show that platelet activation in the absence of surface effects and hemolysis due to high shear are unlikely to occur with this design. Furthermore, vortices that develop in the chamber during filling are predicted to increase blood mixing and provide favorable washing of the chamber walls. A computational-analytical approach such as this may have potential to aid rapid performance evaluation of new devices and streamline the design optimization process.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference18 articles.

1. Acker H. , Mannion, Salmons, and Stephenson, 1986, “An Autologous Biologic Pump Motor,” Journal of Thoracic and Cardiovascular Surgery, Vol. 92(4), pp. 733–745.

2. Araki K. , TaenakaY., et al., 1993, “A Flow Visualization Study of Centrifugal Blood Pumps Developed for Long-Term Usage,” Artificial Organs, Vol. 17(5), pp. 307–312.

3. Araki K. , TaenakaY., et al., 1994, “A Flow Visualization Study of the NCVC Centrifugal Blood Pump,” Artificial Organs, Vol. 18(9), pp. 669–672.

4. Chesler, N. C., 1996, “Ventricular Assist Device Design and Analysis: A Computational Approach,” Ph.D. Thesis, The Harvard Medical School—Massachusetts Institute of Technology Division of Health Sciences and Technology, Cambridge, MA.

5. Farrar D. , and HillJ., 1992, “A New Skeletal Linear-Pull Energy Converter as a Power Source for Prosthetic Circulatory Support Devices,” Journal of Heart and Lung Transplant, Vol. 11, pp. 341–50.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献