Biomechanical Evaluation of Stair Ambulation Using Impedance Control on an Active Prosthesis

Author:

Camargo Jonathan1,Bhakta Krishan1,Herrin Kinsey1,Young Aaron1

Affiliation:

1. College of Engineering, Georgia Institute of Technology , Atlanta, GA 30332

Abstract

Abstract Active prostheses can provide net positive work to individuals with amputation, offering more versatility across locomotion tasks than passive prostheses. However, the effect of powered joints on bilateral biomechanics has not been widely explored for ambulation modes different than level ground and treadmill walking. In this study, we present the bilateral biomechanics of stair ascent and descent with a powered knee-ankle prosthesis compared to the biomechanical profiles of able-bodied subjects at different configurations of stair height between 102 mm and 178 mm. In addition, we include reference profiles from users with passive prostheses for the nominal stair height of 152 mm to place our findings in relation to the typical solution for individuals with transfemoral amputation (TFA). We report the biomechanical profiles of kinematics, kinetics, and power, together with temporal and waveform symmetry and distribution of mechanical energy across the joints. We found that an active prosthesis provides a substantial contribution to mechanical power during stair ascent and power absorption during stair descent and gait patterns like able-bodied subjects. The active prosthesis enables step-over-step gait in stair ascent. This translates into a lower mechanical energy requirement on the intact side, with a 57% reduction of energy at the knee and 26% at the hip with respect to the passive prosthesis. For stair descent, we found a 28% reduction in the negative work done by the intact ankle. These results reflect the benefit of active prostheses, allowing the users to complete tasks more efficiently than passive legs. However, in comparison to able-bodied biomechanics, the results still differ from the ideal patterns. We discuss the limitations that explain this difference and suggest future directions for the design of impedance controllers by taking inspiration from the biological modulation of the knee moment as a function of the stair height.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference42 articles.

1. Etiology of Above-Knee Amputations in the United States: Is Periprosthetic Joint Infection an Emerging Cause?;Clin. Orthop. Relat. Res.,2018

2. The Importance of Additional Mid Swing Toe Clearance for Amputees;Can. Prosthet. Orthot. J.,2018

3. Active Lower Limb Prosthetics: A Systematic Review of Design Issues and Solutions;Biomed. Eng. Online,2016

4. Design and Control of a Powered Transfemoral Prosthesis;Int. J. Rob. Res.,2008

5. Multiclass Real-Time Intent Recognition of a Powered Lower Limb Prosthesis;IEEE Trans Biomed. Eng.,2010

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3