Virtual Axis Finder: A New Method to Determine the Two Kinematic Axes of Rotation for the Tibio-Femoral Joint

Author:

Roland Michelle1,Hull M. L.2,Howell S. M.3

Affiliation:

1. Biomedical Engineering Program, One Shields Ave., University of California, Davis, CA 95616

2. Biomedical Engineering Program and Department of Mechanical Engineering, One Shields Ave., University of California, Davis, CA 95616

3. Department of Mechanical Engineering, One Shields Ave., University of California, Davis, CA 95616

Abstract

The tibio-femoral joint has been mechanically approximated with two fixed kinematic axes of rotation, the longitudinal rotational (LR) axis in the tibia and the flexion-extension (FE) axis in the femur. The mechanical axis finder developed by Hollister et al. (1993, “The Axes of Rotation of the Knee,” Clin. Orthop. Relat. Res., 290, pp. 259–268) identified the two fixed axes but the visual-based alignment introduced errors in the method. Therefore, the objectives were to develop and validate a new axis finding method to identify the LR and FE axes which improves on the error of the mechanical axis finder. The virtual axis finder retained the concepts of the mechanical axis finder but utilized a mathematical optimization to identify the axes. Thus, the axes are identified in a two-step process: First, the LR axis is identified from pure internal-external rotation of the tibia and the FE axis is identified after the LR axis is known. The validation used virtual simulations of 3D video-based motion analysis to create relative motion between the femur and tibia during pure internal-external rotation, and flexion-extension with coupled internal-external rotation. The simulations modeled tibio-femoral joint kinematics and incorporated 1 mm of random measurement error. The root mean squared errors (RMSEs) in identifying the position and orientation of the LR and FE axes with the virtual axis finder were 0.45 mm and 0.20 deg, and 0.11 mm and 0.20 deg, respectively. These errors are at least two times better in position and seven times better in orientation than those of the mechanical axis finder. Variables, which were considered a potential source of variation between joints and/or measurement systems, were tested for their sensitivity to the RMSE of identifying the axes. Changes in either the position or orientation of a rotational axis resulted in high sensitivity to translational RMSE (6.8 mm of RMSE per mm of translation) and rotational RMSE (1.38 deg of RMSE per degree of rotation), respectively. Notwithstanding these high sensitivities, corresponding errors can be reduced by segmenting the range of motion into regions where changes in either position or orientation are small. The virtual axis finder successfully increased the accuracy of the mechanical axis finder when the axes of motion are fixed with respect to the bones, but must be used judiciously in applications which do not have fixed axes of rotation.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference38 articles.

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3