An Automated Kinematic Measurement System for Sagittal Plane Murine Head Impacts

Author:

McInnes Kurt A.1,Abebe Zelalem A.1,Whyte Thomas1,Bashir Asma2,Barron Carlos2,Wellington Cheryl L.3,Cripton Peter A.4

Affiliation:

1. Department of Mechanical Engineering, University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, BC V6T 1Z4, Canada; International Collaboration on Repair Discoveries, 818 West 10th Avenue, Vancouver, BC V5Z 1M9, Canada

2. Department of Pathology and Laboratory Medicine, University of British Columbia, Rm. G227 – 2211 Wesbrook Mall, Vancouver, BC V6T 2B5, Canada; Djavad Mowafaghian Centre for Brain Health, University of British Columbia, 2215 Wesbrook Mall, Vancouver, BC V6T 1Z3, Canada

3. Department of Pathology and Laboratory Medicine, University of British Columbia, Rm. G227 – 2211 Wesbrook Mall, Vancouver, BC V6T 2B5, Canada; Djavad Mowafaghian Centre for Brain Health, University of British Columbia, 2215 Wesbrook Mall, Vancouver, BC V6T 1Z3, Canada; International Collaboration on Repair Discoveries, 818 West 10th Avenue, Vancouver, BC V5Z 1M9, Canada

4. Department of Mechanical Engineering, University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, BC V6T 1Z4, Canada; International Collaboration on Repair Discoveries, 818 West 10th Avenue, Vancouver, BC V5Z 1M9, Canada; Department of Orthopaedics, University of British Columbia, 11th Floor - 2775 Laurel Street Vancouver, BC V5Z 1M9, Canada; School of Biomedical Engineering, Unive

Abstract

Abstract Mild traumatic brain injuries are typically caused by nonpenetrating head impacts that accelerate the skull and result in deformation of the brain within the skull. The shear and compressive strains caused by these deformations damage neural and vascular structures and impair their function. Accurate head acceleration measurements are necessary to define the nature of the insult to the brain. A novel murine head tracking system was developed to improve the accuracy and efficiency of kinematic measurements obtained with high-speed videography. A three-dimensional (3D)-printed marker carrier was designed for rigid fixation to the upper jaw and incisors with an elastic strap around the snout. The system was evaluated by impacting cadaveric mice with the closed head impact model of engineered rotational acceleration (CHIMERA) system using an energy of 0.7 J (5.29 m/s). We compared the performance of the head-marker system to the previously used skin-tracking method and documented significant improvements in measurement repeatability (aggregate coefficient of variation (CV) within raters from 15.8 to 1.5 and between raters from 15.5 to 1.5), agreement (aggregate percentage error from 24.9 to 8.7), and temporal response (aggregate temporal curve agreement from 0.668 to 0.941). Additionally, the new system allows for automated software tracking, which dramatically decreases the analysis time required (74% reduction). This novel head tracking system for mice offers an efficient, reliable, and real-time method to measure head kinematics during high-speed impacts using CHIMERA or other rodent or small mammal head impact models.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference37 articles.

1. Report to Congress on Traumatic Brain Injury in the United States: Epidemiology and Rehabilitation;GA Centers for Disease Control and Prevention,2015

2. The Nature, Distribution and Causes of Traumatic Brain Injury;Brain Pathol. (Zurich, Switzerland),1995

3. Biomechanics of Concussion;Clin. Sports Med.,2011

4. Basics of the Biomechanics of Brain Injury,2017

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3