Abstract
The heat transfer across an air-filled partitioned square enclosure is studied experimentally using a differential interferometer. The partition was located centrally inside the enclosure, parallel to the two isothermal differentially heated vertical walls, and extended the full height of the enclosure. The top and bottom horizontal walls of the enclosure were maintained adiabatic. A parametric study has been carried out using different partitions, focusing attention on the effect of partition thermal resistance as well as the interaction of surface radiation and natural convection, and on the total heat transfer between the vertical walls, inside the enclosure. Correlations, valid for the laminar range, are proposed.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Reference21 articles.
1. Anderson
R.
, and BejanA., 1981, “Heat Transfer Through Single and Double Vertical Walls in Natural Convection: Theory and Experiment,” International Journal of Heat and Mass Transfer, Vol. 24, No. 10, pp. 1611–1620.
2. Bajorek
S. M.
, and LloydJ. R., 1982, “Experimental Investigation of Natural Convection in Partitioned Enclosures,” ASME JOURNAL OF HEAT TRANSFER, Vol. 104, pp. 527–532.
3. Balaji
C.
, and VenkateshanS. P., 1993, “Interaction of Surface Radiation with Free Convection in a Square Cavity,” International Journal of Heat and Fluid Flow, Vol. 14, No. 3, pp. 260–267.
4. Black
W. Z.
, and CarrW. W., 1971, “Application of Differential Interferometer to the Measurement of Heat Transfer Coefficients,” Review of Scientific Instruments, Vol. 42, pp. 337–340.
5. Coleman, H. W., and Steele, Jr., W. G., 1989, Experimentation and Uncertainty Analysis for Engineers, John Wiley and Sons, New York.
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献