Affiliation:
1. Fokker-VFW International, Amsterdam, The Netherlands
2. Purdue University, West Lafayette, IN
Abstract
Experimental and analytical studies are made of the factors governing the mean drop size of sprays produced by prefilming airblast atomizers. Three geometrically similar atomizers, having cross-sectional areas in the ratio of 1:4:16, and with prefilmer lip diameters of 19.05, 38.10 and 76.20 mm, are employed. It is found that spray quality declines with increase in atomizer size. Analysis of the experimental data shows that the relationship between the key variables and mean drop size is described satisfactorily by the following dimensionally correct expression: SMD=0.073(σLρAUA2)0.6(ρLρA)0.1Dp0.4(1+WLWA)+0.015(μL2DPσLρL)0.5(1+WLWA)
Publisher
American Society of Mechanical Engineers
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献