Impact of Variation in Interleaflet Triangle Height Between Fused Leaflets in the Functionally Bicuspid Aortic Valve on Hemodynamics and Tissue Biomechanics

Author:

Sundström Elias1,Tretter Justin T.2

Affiliation:

1. Department of Otolaryngology—Head and Neck Surgery, University of Cincinnati, 231 Albert Sabin Way, Cincinnati, OH 45267

2. Heart Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, OH 45229; Department of Pediatrics, University of Cincinnati, Cincinnati, OH 45267

Abstract

Abstract There is fusion between two leaflets in functionally bicuspid (bileaflet) aortic valves with trisinuate aortic root. The degree of fusion inversely correlates with variation in the interleaflet triangle height (“commissural height”). We aimed to determine the hemodynamics and biomechanical response in the thoracic aorta due to variations in the commissural height between fused leaflets in a bicuspid aortic valve with raphe. A three-dimensional (3D) aortic valve model was reconstructed using cardiac magnetic resonance (CMR) imaging from a patient with a normal trileaflet aortic valve. Fluid–structure interaction (FSI) simulations were used to investigate the effect of variation in commissural height between the coronary leaflets with leaflet fusion, and this was contrasted to a case with a normal trileaflet valve. Phase-contrast CMR was used for validation of the simulated hemodynamics. The aorta and leaflet tissues were treated as hyperelastic materials. In the normal trileaflet aortic valve, two counter-rotating vortex cores develop within the root at peak systole and interact with the walls of the ascending aorta. However, in the bicuspid aortic valve with fusion between the coronary leaflets, the vortex system becomes more asymmetric. This correlates with more recirculation of flow toward the fusion side of the aortic root. The peak velocity, pressure gradient, wall shear stress, and strain levels increase approximately linear with decreasing commissural height and increasing leaflet fusion. Decreasing interleaflet triangle height between the fused leaflets in bicuspid aortic valves with raphe results in linear elevation of wall shear stress at the sinutubular junction and proximal ascending aorta.

Publisher

ASME International

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3