Biomechanical Robustness of a Contemporary Cementless Stem to Surgical Variation in Stem Size and Position

Author:

Al-Dirini Rami M. A.1,O'Rourke Dermot2,Huff Daniel3,Martelli Saulo2,Taylor Mark1

Affiliation:

1. Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide 5043, Australia e-mail:

2. Medical Device Research Institute, College of Science and Engineering, Flinders University, Adelaide 5043, Australia

3. DePuy Synthes, Johnson and Johnson, Warsaw, IN 46581

Abstract

Successful designs of total hip replacement (THR) need to be robust to surgical variation in sizing and positioning of the femoral stem. This study presents an automated method for comprehensive evaluation of the potential impact of surgical variability in sizing and positioning on the primary stability of a contemporary cementless femoral stem (Corail®, DePuy Synthes). A patient-specific finite element (FE) model of a femur was generated from computed tomography (CT) images from a female donor. An automated algorithm was developed to span the plausible surgical envelope of implant positions constrained by the inner cortical boundary. The analysis was performed on four stem sizes: oversized, ideal (nominal) sized, and undersized by up to two stem sizes. For each size, Latin hypercube sampling was used to generate models for 100 unique alignment scenarios. For each scenario, peak hip contact and muscle forces published for stair climbing were scaled to the donor's body weight and applied to the model. The risk of implant loosening was assessed by comparing the bone–implant micromotion/strains to thresholds (150 μm and 7000 με) above which fibrous tissue is expected to prevail and the periprosthetic bone to yield, respectively. The risk of long-term loosening due to adverse bone resorption was assessed using bone adaptation theory. The range of implant positions generated effectively spanned the available intracortical space. The Corail stem was found stable and robust to changes in size and position, with the majority of the bone–implant interface undergoing micromotion and interfacial strains that are well below 150 μm and 7000 με, respectively. Nevertheless, the range of implant positions generated caused an increase of up to 50% in peak micromotion and up to 25% in interfacial strains, particularly for retroverted stems placed in a medial position.

Funder

Australian Research Council

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3