3D MRI-Based Anisotropic FSI Models With Cyclic Bending for Human Coronary Atherosclerotic Plaque Mechanical Analysis

Author:

Tang Dalin1,Yang Chun2,Kobayashi Shunichi3,Zheng Jie4,Woodard Pamela K.4,Teng Zhongzhao1,Billiar Kristen5,Bach Richard6,Ku David N.7

Affiliation:

1. Department of Mathematical Sciences, Worcester Polytechnic Institute, Worcester, MA 01609

2. Department of Mathematical Sciences, Worcester Polytechnic Institute, Worcester, MA 01609; School of Mathematical Sciences, Beijing Normal University, Beijing, China

3. Division of Creative Engineering, Shinshu University, Ueda, Nagano, Japan

4. Mallinkcrodt Institute of Radiology, Washington University, St. Louis, MO 63110

5. Department of Biomedical Engineering, Worcester Polytechnic Institute, Worcester, MA 01609

6. Division of Cardiovascular Diseases, Washington University, St. Louis, MO 63110

7. School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332

Abstract

Heart attack and stroke are often caused by atherosclerotic plaque rupture, which happens without warning most of the time. Magnetic resonance imaging (MRI)-based atherosclerotic plaque models with fluid-structure interactions (FSIs) have been introduced to perform flow and stress/strain analysis and identify possible mechanical and morphological indices for accurate plaque vulnerability assessment. For coronary arteries, cyclic bending associated with heart motion and anisotropy of the vessel walls may have significant influence on flow and stress/strain distributions in the plaque. FSI models with cyclic bending and anisotropic vessel properties for coronary plaques are lacking in the current literature. In this paper, cyclic bending and anisotropic vessel properties were added to 3D FSI coronary plaque models so that the models would be more realistic for more accurate computational flow and stress/strain predictions. Six computational models using one ex vivo MRI human coronary plaque specimen data were constructed to assess the effects of cyclic bending, anisotropic vessel properties, pulsating pressure, plaque structure, and axial stretch on plaque stress/strain distributions. Our results indicate that cyclic bending and anisotropic properties may cause 50–800% increase in maximum principal stress (Stress-P1) values at selected locations. The stress increase varies with location and is higher when bending is coupled with axial stretch, nonsmooth plaque structure, and resonant pressure conditions (zero phase angle shift). Effects of cyclic bending on flow behaviors are more modest (9.8% decrease in maximum velocity, 2.5% decrease in flow rate, 15% increase in maximum flow shear stress). Inclusion of cyclic bending, anisotropic vessel material properties, accurate plaque structure, and axial stretch in computational FSI models should lead to a considerable improvement of accuracy of computational stress/strain predictions for coronary plaque vulnerability assessment. Further studies incorporating additional mechanical property data and in vivo MRI data are needed to obtain more complete and accurate knowledge about flow and stress/strain behaviors in coronary plaques and to identify critical indicators for better plaque assessment and possible rupture predictions.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference50 articles.

1. Atherosclerotic Plaque Rupture and Thrombosis, Evolving Concept;Fuster;Circulation

2. The Role of Fluid Mechanics in the Localization and Detection of Atherosclerosis;Giddens;ASME J. Biomech. Eng.

3. From Vulnerable Plaque to Vulnerable Patient: A Call for New Definitions and Risk Assessment Strategies: I;Naghavi;Circulation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3