Affiliation:
1. Ampex Corporation, Redwood City, Calif.
Abstract
Experimental results on the interior and the exit region film-thickness measurements of self-acting foil bearings are presented and discussed. These measurements were made with capacitive sensors and conductive foils. The measured and predicted values agree very well within the range of nondimensional parameters, h0/R, from 10−4 to 10−3 and, T/μU, from 105 to 106. The agreement deviates for values beyond these ranges. Empirical expressions for predicting the constant and minimum film thickness applicable beyond these ranges are also presented. They are valid within the range of h0/R from 5(10)−5 to 10−2 and T/μU from 104 to 105. Growing sinusoidal film thickness in the exit region was also observed, measured, and checked with theoretical predictions.
Cited by
22 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献