Affiliation:
1. Department of Mechanical Engineering, The University of British Columbia, Vancouver, B. C., Canada V6T 1W5
Abstract
An extensive wind tunnel test program is described which assesses the relative influence of system parameters on the Savonius rotor performance. The parametric study leads to an optimum configuration with an increase in efficiency by around 100 percent compared to the reported efficiency of ≈12–15 percent. Of particular interest is the blockage correction procedure which is vital for application of the wind tunnel results to a prototype design, and facilitates comparison of data obtained by other investigators. Next, using the concept of a central vortex, substantiated by a flow visualization study, a semiempirical approach to predict the rotor performance using measured stationary blade pressure data is developed. The simple approach promises to be quite effective in predicting the rotor performance, even in the presence of blockage, and should prove useful at least in the preliminary design stages.
Subject
Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment
Cited by
104 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献