Non-Invasive Optical Blood Glucose Measurement based on Discrete Fourier Transform and Fast Artificial Neural Network: Fasting Normal Glucose Participants Case Study

Author:

Jenie Renan Prasta1,Damayanthi Evy2,Irzaman Irzaman3,Rimbawan Rimbawan2,Sukandar Dadang2,Nurdin Naufal Muharam2,Alatas Husin3

Affiliation:

1. Community Nutrition and Physics Department, Bogor Agricultural University, Jl. Lingkar Kampus, Kampus IPB, Babakan, Darmaga, Bogor, Jawa Barat 16680, Indonesia

2. Community Nutrition Department, Bogor Agricultural University, Jl. Lingkar Kampus, Kampus IPB, Babakan, Darmaga, Bogor, Jawa Barat 16680, Indonesia

3. Physics Department, Bogor Agricultural University, Jalan Meranti Kampus IPB Darmaga, Bogor, Jawa Barat 16680, Indonesia

Abstract

A prototype non-invasive blood glucose level measurement optical device (NI-BGL-MOD) has been developed. The NI-BGL-MOD uses a discrete Fourier transform (DFT) method and a fast artificial neural network algorithm to optimize device performance. The appropriate light-emitting diode for the sensory module was selected based on near-infrared spectrophotometry of a blood glucose model and human blood. DFT is implemented in an analog-to-digital converter module. An in vitro trial using the blood glucose model along with a clinical trial involving 110 participants were conducted to evaluate the performance of the prototype. The root-mean-square error of the prototype was 10.8 mg/dl in the in vitro trial and 3.64 mg/dl in the clinical trial, which is lower than the ISO-15197:2016 mandated value of 10 mg/dl. In each trial, consensus error grid analysis indicated that the measurement error was within the safe range. The sensitivity and specificity of the prototype were 0.83 (0.36, 1.00) and 0.90 (0.55, 1.00) in the in vitro trial and 0.81 (0.75, 0.85) and 0.83 (0.78, 0.87) in the clinical trial, respectively. In general, the proposed NI-BGL-MOD demonstrated good performance than gold-standard measurement. Key words: Non-invasive blood glucose measurement, optical device, discrete Fourier transform, multi-formulatric regression, fast artificial neural network

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. A Proposed Algorithm Based on Artificial Intelligence to Optimize the Ratio of Food Combinations on a Meal Plate;Advances in Health Sciences Research;2023

2. Development of blood hemoglobin level early detection device based on a noninvasive optical platform;Heliyon;2022-11

3. Fourier Transform Infra-Red spectrophotometry observation to find appropriate wavelength for non-invasive blood glucose level measurement optical device;Journal of Physics: Conference Series;2021-05-01

4. Non-invasive measurement of blood glucose biomimetics with the reflectance method on near-infrared light source;THE 4TH INTERNATIONAL CONFERENCE ON MATHEMATICS AND SCIENCE EDUCATION (ICoMSE) 2020: Innovative Research in Science and Mathematics Education in The Disruptive Era;2021

5. Non-invasive hemoglobin blood level measurement system;THE 4TH INTERNATIONAL CONFERENCE ON MATHEMATICS AND SCIENCE EDUCATION (ICoMSE) 2020: Innovative Research in Science and Mathematics Education in The Disruptive Era;2021