A Hybrid Coil/Polymer Device for Occlusion of Cerebral Aneurysms

Author:

Xu Fangmin1,Hart Kevin2,Flanagan Claire E.1,Nacker John C.2,Moftakhar Roham3,Aagaard-Kienitz Beverly4,Consigny Daniel W.5,Grinde Julie R.5,Crone Wendy C.6,Masters Kristyn S.1

Affiliation:

1. Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53706

2. Department of Engineering Physics, University of Wisconsin-Madison, Madison, WI 53706

3. Department of Neurological Surgery, University of Wisconsin-Madison, Madison, WI 53792

4. Department of Neurological Surgery, University of Wisconsin-Madison, Madison, WI 53792; Department of Radiology, University of Wisconsin-Madison, Madison, WI 53792

5. Department of Radiology, University of Wisconsin-Madison, Madison, WI 53792

6. Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53706; Department of Engineering Physics, University of Wisconsin-Madison, Madison, WI 53706

Abstract

The treatment of cerebral aneurysms is frequently accomplished via endovascular delivery of metal coils in order to occlude the aneurysm and prevent rupture. This procedure involves imprecise packing of large lengths of wire into the aneurysm and often results in high rates of aneurysm recanalization. Over time, this incomplete aneurysm occlusion can lead to aneurysm enlargement, which may have fatal consequences. This report describes the fabrication and preliminary testing of a novel aneurysm occlusion device composed of a single metal coil surrounded by a biocompatible polymer shell. These coil-in-shell devices were tested under flow conditions in synthetic in vitro models of saccular aneurysms and deployed in vivo in a short-term porcine aneurysm model to study occlusion efficacy. A single nickel titanium shape memory wire was used to deploy a biocompatible, elastic polymeric shell, leading to aneurysmal sac filling in both in vitro and in vivo aneurysm models. The deployment of this coil-in-shell device in synthetic aneurysm models in vitro resulted in varying degrees of aneurysm occlusion, with less than 2% of trials resulting in significant leakage of fluid into the aneurysm. Meanwhile, in vivo coil-in-shell device implantation in a porcine aneurysm model provided proof-of-concept for successful occlusion, as both aneurysms were completely occluded by the devices. Both in vitro and in vivo studies demonstrated that this coil-in-shell device may be attractive as an alternative to traditional coil embolization methods in some cases, allowing for a more precise and controlled aneurysm occlusion.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference29 articles.

1. Prevalence and Rupture Rate of Cerebral Aneurysms Discovered During Intra-Arterial Chemotherapy of Brain Tumors;Bourekas;AJNR Am. J. Neuroradiol.

2. Involvement of Internal Elastic Lamina in Development of Induced Cerebral Aneurysms in Rats;Kim;Stroke

3. Etiology of Intracranial Berry Aneurysms;Stehbens;J. Neurosurg.

4. Subarachnoid Haemorrhage;van Gijn;Lancet

5. Endovascular Treatment and Neurointensive Care of Ruptured Aneurysms;Vespa;Crit. Care Clin.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3