Abstract

Parabolic trough collectors are economically and technically attractive options for process heat applications that require temperatures in excess of 200 °C. One of the reasons is that low-cost non-evacuated receivers are used in this type of application. However, at higher temperatures, the performance of non-evacuated receivers deteriorates considerably due to excessive radiation and natural convection losses. A new idea had been preliminarily investigated by the authors both numerically and experimentally. The idea was to introduce a thermally insulating layer to the part of the receiver’s annular gap that does not receive concentrated sunlight from the parabolic mirrors, and the results had been quite promising. This paper presents additional, more extensive experiments on this concept. In these experiments, a cartridge heater is inserted along the axis of the receiver tube of a non-evacuated receiver. The heater is surrounded by a conductive material to ensure uniform heating of the receiver tube. A number of thermocouples are affixed near the inner surface of the receiver as well as on the outer surface of the glass envelope to monitor temperature uniformity. Two sets of experiments are then conducted, one with the insulating layer, and the other without. In each set, the power input is set to a certain level and the receiver temperature is measured once steady state conditions are attained. The power level is then increased, and the measurements are repeated. The heat loss values from each set are compared to determine whether adding the insulating layer enhances receiver performance. Results show that a reduction in heat loss of as much as 15% can be achieved using this design, and collector efficiency can increase by up to about 6%. However, it was also found that the extent of improvement in collector efficiency depends on the operating temperature and direct normal irradiance, with the improvement being more significant at higher temperature applications and at low direct normal irradiance.

Publisher

American Society of Mechanical Engineers

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3