Studies of Power Station Feed Pump Loss of Suction Pressure Incidents

Author:

Cranfield R. R.1

Affiliation:

1. Central Electricity Generating Board, Technology Planning and Research Division, Southampton, UK

Abstract

Open cycle feed systems featuring a deaerator followed by the boiler feed pumps have been subject to unexpected loss in net positive suction head during transient operation. This has been traced to separation at the deaerator storage tank drain and the formation of a steam/water interface in the downcomer to the pumps. The outflow at separation when the storage tank water is subcooled is generally much greater than the maximum suction flow corresponding to the unit rating, but when the tank water boils, as during transients, it may be very much less. Thus with a high suction flow in the boiling mode, the new interface may descend in the downcomer to result in feed pump cavitation, pressure imbalance, vapor locking, severe vibration, damage to the pump and an inability to maintain forward flow. Model tests have been conducted to establish the criterion for the separation in terms of the critical outflow for specific operating conditions as a function of geometric ratios involving tank-water depth and tank/downcomer dimensions. The data obtained although scattered are in general agreement with the data from actual plant and may be used to assess safe operating parameters.

Publisher

ASME International

Subject

Mechanical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3