Affiliation:
1. Division of Orthopedic Surgery and Department of Mechanical Engineering. University of Wisconsin, Madison, WI 53792
2. Division of Orthopedic Surgery and Department of Electrical Engineering. University of Wisconsin, Madison, WI 53792
3. Division of Orthopedic Surgery and Department of Kinesiology. University of Wisconsin, Madison, WI 53792
Abstract
A system was refined for the determination of the bulk ultrasonic wave propagation velocity in small cortical bone specimens. Longitudinal and shear wave propagations were measured using ceramic, piezoelectric 20 and 5 MHz transducers, respectively. Results of the pulse transmission technique were refined via the measurement of the system delay time. The precision and accuracy of the system were quantified using small specimens of polyoxymethylene, polystyrene-butadiene, and high-density polyethylene. These polymeric materials had known acoustic properties, similarity of propagation velocities to cortical bone, and minimal sample inhomogeneity. Dependence of longitudinal and transverse specimen dimensions upon propagation times was quantified. To confirm the consistency of longitudinal wave propagation in small cortical bone specimens (<1.0 mm), cut-down specimens were prepared from a normal rat femur. Finally, cortical samples were prepared from each of ten normal rat femora, and Young’s moduli (Eii), shear moduli (Gij), and Poisson ratios (vij) were measured. For all specimens (bone, polyoxymethylene, polystyrene-butadiene, and high-density polyethylene), strong linear correlations (R2 > 0.997) were maintained between propagation time and distance throughout the size ranges down to less than 0.4 mm. Results for polyoxymethylene, polystyrene-butadiene, and high-density polyethylene were accurate to within 5 percent of reported literature values. Measurement repeatability (precision) improved with an increase in the wave transmission distance (propagating dimension). No statistically significant effect due to the transverse dimension was detected.
Subject
Physiology (medical),Biomedical Engineering
Reference24 articles.
1. Akhter
M. P.
, RaabD. M., TurnerC. H., KimmelD. B., and ReckerR. R., “Characterization of in vivo strain in the rat tibia during external application of a four-point bending load,” J. Biomechanics, Vol. 25, 1992, pp. 1241–1246.
2. Ashman
R. B.
, CowinS. C., Van BuskirkW. C., and RiceJ. C., “A continuous wave technique for the measurement of the elastic properties of cortical bone,” J. Biomechanics, Vol. 17, 1984, pp. 349–361.
3. Hartmann
B.
and JarzynskiJ., “Immersion apparatus for ultrasonic measurements in polymers,” J. Acoust. Soc. Am., Vol. 56, 1974, pp. 1469–1477.
4. Hasegawa
K.
, BurrD. B., and TurnerC. H., “Contribution of collagen and mineral to anisotropy of osteonal bone,” Trans. Ortho. Res. Soc., Vol. 19, 1994, p. 5454.
5. Keaveny
T. M.
, BorchersR. E., GibsonL. J., and HayesW. C., “Theoretical analysis of the experimental artifact in trabecular bone compressive modulus,” J. Biomechanics, Vol. 26, No. 4/5, 1993, pp. 599–607.
Cited by
33 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献