Affiliation:
1. Department of Neurosurgery, Medical College of Wisconsin; and Department of Veterans Affairs Medical Center, Milwaukee, WI 53226
Abstract
While the majority of experimental cervical spine biomechanics research has been conducted using slowly applied forces and/or moments, or dynamically applied forces with contact, little research has been performed to delineate the biomechanics of the human neck under inertial “noncontact” type forces. This study was designed to develop a comprehensive methodology to induce these loads. A minisled pendulum experimental setup was designed to test specimens (such as human cadaver neck) at subfailure or failure levels under different loading modalities including flexion, extension, and lateral bending. The system allows acceleration/deceleration input with varying wave form shapes. The test setup dynamically records the input and output strength information such as forces, accelerations, moments, and angular velocities; it also has the flexibility to obtain the temporal overall and local kinematic data of the cervical spine components at every vertebral level. These data will permit a complete biomechanical structural analysis. In this paper, the feasibility of the methodology is demonstrated by subjecting a human cadaver head-neck complex with intact musculature and skin under inertial flexion and extension whiplash loading at two velocities.
Subject
Physiology (medical),Biomedical Engineering
Cited by
28 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献