The Relationship of Normal and Abnormal Microstructural Proliferation to the Mitral Valve Closure Sound
Author:
Einstein Daniel R.1, Kunzelman Karyn S.2, Reinhall Per G.3, Nicosia Mark A.4, Cochran Richard P.2
Affiliation:
1. Department of Bioengineering, University of Washington, Seattle, Washington 98195 2. Central Maine Medical Center, Central Maine Heart and Vascular Institute, Lewiston, Maine 04240 3. Department of Mechanical Engineering, University of Washington, Seattle, Washington 98195 4. University of Minnesota, Department of Biomedical Engineering, Minneapolis, Minnesota 55455
Abstract
Background : Many diseases that affect the mitral valve are accompanied by the proliferation or degradation of tissue microstructure. The early acoustic detection of these changes may lead to the better management of mitral valve disease. In this study, we examine the nonstationary acoustic effects of perturbing material parameters that characterize mitral valve tissue in terms of its microstructural components. Specifically, we examine the influence of the volume fraction, stiffness and splay of collagen fibers as well as the stiffness of the nonlinear matrix in which they are embedded. Methods and Results: To model the transient vibrations of the mitral valve apparatus bathed in a blood medium, we have constructed a dynamic nonlinear fluid-coupled finite element model of the valve leaflets and chordae tendinae. The material behavior for the leaflets is based on an experimentally derived structural constitutive equation. The gross movement and small-scale acoustic vibrations of the valvular structures result from the application of physiologic pressure loads. Material changes that preserved the anisotropy of the valve leaflets were found to preserve valvular function. By contrast, material changes that altered the anisotropy of the valve were found to profoundly alter valvular function. These changes were manifest in the acoustic signatures of the valve closure sounds. Abnormally, stiffened valves closed more slowly and were accompanied by lower peak frequencies. Conclusion: The relationship between stiffness and frequency, though never documented in a native mitral valve, has been an axiom of heart sounds research. We find that the relationship is more subtle and that increases in stiffness may lead to either increases or decreases in peak frequency depending on their relationship to valvular function.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference40 articles.
1. Cole, W. G., Chan, D., Hickey, A. J., and Wilcken, D. E., 1984, “Collagen Composition of Normal and Myxomatous Human Mitral Heart Valves,” Biochem. J., 219, pp. 451–460. 2. Fornes, P., Heudes, D., Fuzellier, J. F., Tixier, D., Bruneval, P., and Carpentier, A., 1999, “Correlation Between Clinical and Histologic Patterns of Degenerative Mitral Valve Insufficiency: A Histomorphometric Study of 130 Excised Segments,” Cardiovasc. Pathol., 8, pp. 81–92. 3. Barber, J. E., Kasper, F. K., Ratliff, N. B., Cosgrove, D. M., Griffin, B. P., and Vesely, I., 2001, “Mechanical Properties of Myxomatous Mitral Valves,” J. Thorac. Cardiovasc. Surg., 122, pp. 955–962. 4. Lis, Y., Burleigh, D., Parker, D. J., Child, A. H., Hogg, J., and Davies, M. J., 1987, “Biochemical Characterization of Individual Normal, Floppy and Rheumatic Human Mitral Valves,” Biochem. J., 244, pp. 597–603. 5. Rabkin, E., Aikawa, M., Stone, J. R., Fukumoto, Y., Libby, P., and Schoen, F. J., 2001, “Activated Interstitial Myofibroblasts Express Catabolic Enzymes and Mediate Matrix Remodeling in Myxomatous Heart Valves,” Circulation, 104, pp. 2525–2532.
Cited by
40 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|