Abstract

Abstract For standard “off-the-shelf” knee replacement procedures, surgeons use X-ray images to aid implant selection from a limited number of models and sizes. This can lead to complications and the need for implant revision due to poor implant fit. Customized solutions have been shown to improve results but require increased preoperative assessment (Computed Tomography or Magnetic Resonance Imaging), longer lead times, and higher costs which have prevented widespread adoption. To attain the benefits of custom implants, whilst avoiding the limitations of currently available solutions, a fully automated mass-customization pipeline, capable of developing customized implant designs for fabrication via additive manufacturing from calibrated X-rays, is proposed. The proof-of-concept pipeline uses convolutional neural networks to extract information from biplanar X-ray images, point depth, and statistical shape models to reconstruct the anatomy, and application programming interface scripts to generate various customized implant designs. The pipeline was trained using data from the Korea Institute of Science and Technology Information. Thirty subjects were used to test the accuracy of the anatomical reconstruction, ten from this data set, and a further 20 independent subjects obtained from the Osteoarthritis Initiative. An average root-mean-squared error of 1.00 mm was found for the femur test cases and 1.07 mm for the tibia. Three-dimensional (3D) distance maps of the output components demonstrated these results corresponded to well-fitting components, verifying automatic customization of knee replacement implants is feasible from 2D medical imaging.

Publisher

ASME International

Subject

Computer Graphics and Computer-Aided Design,Computer Science Applications,Mechanical Engineering,Mechanics of Materials

Reference45 articles.

1. Analysis of Total Knee Arthroplasty Revision Causes;Postler;BMC Musculoskeletal Disorders

2. Preoperative Planning in Primary Total Knee Arthroplasty;Tanzer;J. Am. Acad. Orthopaedic Surgeons,2016

3. Customized Knee Arthroplasty and the Role of Preoperative Imaging;O’Connor;Musculoskeletal Imaging,2013

4. Reliability of Preoperative Measurement With Standardized Templating in Total Knee Arthroplasty;Hernandez-Vaquero;World J. Orthopaedics,2013

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3