Optimal Determination of Respiratory Airflow Patterns for a General Multicompartment Lung Mechanics System With Nonlinear Resistance and Compliance Parameters

Author:

Paul Hou Saing1,Meskin Nader2,Haddad Wassim M.3

Affiliation:

1. Singapore Institute of Manufacturing Technology, A*STAR, Singapore 638075 e-mail:

2. Assistant Professor Electrical Engineering Department, Qatar University, Doha 2713, Qatar e-mail:

3. Professor School of Aerospace Engineering, Georgia Institute of Technology, Atlanta, GA 30332 e-mail:

Abstract

In this paper, we develop a framework for determining optimal respiratory airflow patterns for a multicompartment lung mechanics system with nonlinear resistance and compliance parameters. First, a nonlinear multicompartment lung mechanics model that accounts for nonlinearities in both the airway resistances and the lung compliances is developed. In particular, we assume that the resistive losses are characterized by a Rohrer-type model with resistive losses defined as the sum of linear and quadratic terms of the airflow. The proposed model is more realistic than those presented in the literature, since it takes into account the heterogeneity of lung anatomy and function as well as the nonlinearity of lung resistance and compliance parameters. This model can be used to provide a better understanding of pulmonary function as well as the process of mechanical ventilation. Next, using the proposed nonlinear multicompartment lung model, we develop a framework for determining optimal respiratory airflow patterns. Specifically, an optimization criterion that involves the minimization of the oxygen consumption of the lung muscles and lung volume acceleration for the inspiratory phase, and the minimization of the elastic potential energy and rapid airflow rate changes for the expiratory phase is formulated and solved. The solution to the formulated optimization problem is derived using classical calculus of variation techniques. Finally, several illustrative numerical examples are presented to illustrate the efficacy of the proposed nonlinear multicompartment lung model and the corresponding optimal airflow patterns. Comparison with experimental data shows that our nonlinear resistance model predicts the airflow patterns more accurately than linear resistance models. Moreover, the optimization criterion used in this paper also provides a more accurate prediction of the optimal airflow patterns.

Publisher

ASME International

Subject

Computer Science Applications,Mechanical Engineering,Instrumentation,Information Systems,Control and Systems Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Automatic Detection of Endotracheal Intubation During the Anesthesia Procedure;Journal of Dynamic Systems, Measurement, and Control;2016-08-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3