The Relation Between Collagen Fibril Kinematics and Mechanical Properties in the Mitral Valve Anterior Leaflet

Author:

Liao Jun1,Yang Lin2,Grashow Jonathan1,Sacks Michael S.1

Affiliation:

1. Engineered Tissue Mechanics Laboratory, Department of Bioengineering, and the McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA 15219

2. National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, Upton, NY 11973

Abstract

We have recently demonstrated that the mitral valve anterior leaflet (MVAL) exhibited minimal hysteresis, no strain rate sensitivity, stress relaxation but not creep (Grashow et al., 2006, Ann Biomed Eng., 34(2), pp. 315–325;Grashow et al., 2006, Ann Biomed. Eng., 34(10), pp. 1509–1518). However, the underlying structural basis for this unique quasi-elastic mechanical behavior is presently unknown. As collagen is the major structural component of the MVAL, we investigated the relation between collagen fibril kinematics (rotation and stretch) and tissue-level mechanical properties in the MVAL under biaxial loading using small angle X-ray scattering. A novel device was developed and utilized to perform simultaneous measurements of tissue level forces and strain under a planar biaxial loading state. Collagen fibril D-period strain (εD) and the fibrillar angular distribution were measured under equibiaxial tension, creep, and stress relaxation to a peak tension of 90N∕m. Results indicated that, under equibiaxial tension, collagen fibril straining did not initiate until the end of the nonlinear region of the tissue-level stress-strain curve. At higher tissue tension levels, εD increased linearly with increasing tension. Changes in the angular distribution of the collagen fibrils mainly occurred in the tissue toe region. Using εD, the tangent modulus of collagen fibrils was estimated to be 95.5±25.5MPa, which was ∼27 times higher than the tissue tensile tangent modulus of 3.58±1.83MPa. In creep tests performed at 90N∕m equibiaxial tension for 60min, both tissue strain and εD remained constant with no observable changes over the test length. In contrast, in stress relaxation tests performed for 90minεD was found to rapidly decrease in the first 10min followed by a slower decay rate for the remainder of the test. Using a single exponential model, the time constant for the reduction in collagen fibril strain was 8.3min, which was smaller than the tissue-level stress relaxation time constants of 22.0 and 16.9min in the circumferential and radial directions, respectively. Moreover, there was no change in the fibril angular distribution under both creep and stress relaxation over the test period. Our results suggest that (1) the MVAL collagen fibrils do not exhibit intrinsic viscoelastic behavior, (2) tissue relaxation results from the removal of stress from the fibrils, possibly by a slipping mechanism modulated by noncollagenous components (e.g. proteoglycans), and (3) the lack of creep but the occurrence of stress relaxation suggests a “load-locking” behavior under maintained loading conditions. These unique mechanical characteristics are likely necessary for normal valvular function.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference52 articles.

1. Morphology of the Human Mitral Valve. II. The Value Leaflets;Ranganathan;Circulation

2. Surface Strains in the Anterior Leaflet of the Functioning Mitral Valve;Sacks;Ann. Biomed. Eng.

3. Effects of Papillary Muscle Position on In-Vitro Dynamic Strain on the Porcine Mitral Valve;He;J. Heart Valve Dis.

4. In-Vivo Dynamic Deformation of the Mitral Valve Anterior Leaflet;Sacks;Ann. Thorac. Surg.

5. Biaxial Mechanical Behavior of Excised Porcine Mitral Valve Leaflets;May-Newman;Am. J. Physiol.