Passive Biaxial Mechanical Response of Aged Human Iliac Arteries
Author:
Schulze-Bauer Christian A. J.1, Mo¨rth Christian2, Holzapfel Gerhard A.1
Affiliation:
1. Institute for Structural Analysis, Computational Biomechanics, Graz University of Technology, 8010 Graz, Schiesstattgasse 14-B, Austria 2. Institute of Pathology, Karl-Franzens-University Graz, 8036 Graz, Auenbruggerplatz 25, Austria
Abstract
Inflation and extension tests of arteries are essential for the understanding of arterial wall mechanics. Data for such tests of human arteries are rare. At autopsy we harvested 10 non-diseased external iliac arteries of aged subjects (52–87 yrs). Structural homogeneity was ensured by means of ultrasound imaging, and anamneses of patients were recorded. We measured the axial in situ stretches, load-free geometries and opening angles. Passive biaxial mechanical responses of preconditioned cylindrical specimens were studied in 37°C calcium-free Tyrode solution under quasistatic loading conditions. Specimens were subjected to pressure cycles varying from 0 to 33.3kPa (250mmHg) at nine fixed axial loads, varying from 0 to 9.90N. For the description of the load-deformation behavior we employed five “two-dimensional” orthotropic strain-energy functions frequently used in arterial wall mechanics. The associated constitutive models were compared in regard to their ability of representing the experimental data. Histology showed that the arteries were of the muscular type. In contrast to animal arteries they exhibited intimal layers of considerable thickness. The average ratio of wall thickness to outer diameter was 7.7, which is much less than observed for common animal arteries. We found a clear correlation between age and the axial in situ stretch λis(r=−0.72,P=0.03), and between age and distensibility of specimens, i.e. aged specimens are less distensible. Axial in situ stretches were clearly smaller (1.07±0.09,mean±SD) than in animal arteries. For one specimen λis was even smaller than 1.0, i.e. the vessel elongated axially upon excision. The nonlinear and anisotropic load-deformation behavior showed small hystereses. For the majority of specimens we observed axial stretches smaller than 1.3 and circumferential stretches smaller than 1.1 for the investigated loading range. Data from in situ inflation tests showed a significant increase of the axial stretch with intraluminal pressure. Thus, for this type of artery the axial in situ stretch of a non-pressurized vessel is not representative of the axial in vivo stretch. None of the constitutive models were able to represent the deformation behavior of the entire loading range. For the physiological loading range, however, some of the models achieved good agreement with the experimental data.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference37 articles.
1. Holzapfel, G. A., 2000, Nonlinear Solid Mechanics, A Continuum Approach for Engineering, John Wiley and Sons, Chichester. 2. Holzapfel, G. A., Gasser, T. C., and Ogden, R. W., 2000, “A New Constitutive Framework for Arterial Wall Mechanics and a Comparative Study of Material Models,” J. Elast., 61, pp. 1–48. 3. Gasser, T. C., Schulze-Bauer, C. A. J., and Holzapfel, G. A., 2002, “A Three-dimensional Finite Element Model for Arterial Clamping,” J. Biomech. Eng., 124, pp. 355–363. 4. Holzapfel, G. A., Stadler, M., and Schulze-Bauer, C. A. J., 2002, “A Layer-Specific 3D-Model for the Finite Element Simulation of Balloon Angioplasty using MR Imaging and Mechanical Testing,” Ann. Biomed. Eng., 30, pp. 753–767. 5. The, S. H., Gussenhoven, E. J., Pieterman, H., van Bortel, L. M., Li, W., Roelandt, J. R., de Feyter, P., and Van Urk, H., 1995, “Assessment of Regional Vascular Distensibility in Diseased Iliofemoral Arteries by Intravascular Ultrasound,” Ultrasound Med. Biol., 21, pp. 17–24.
Cited by
150 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|