Passive Biaxial Mechanical Response of Aged Human Iliac Arteries

Author:

Schulze-Bauer Christian A. J.1,Mo¨rth Christian2,Holzapfel Gerhard A.1

Affiliation:

1. Institute for Structural Analysis, Computational Biomechanics, Graz University of Technology, 8010 Graz, Schiesstattgasse 14-B, Austria

2. Institute of Pathology, Karl-Franzens-University Graz, 8036 Graz, Auenbruggerplatz 25, Austria

Abstract

Inflation and extension tests of arteries are essential for the understanding of arterial wall mechanics. Data for such tests of human arteries are rare. At autopsy we harvested 10 non-diseased external iliac arteries of aged subjects (52–87 yrs). Structural homogeneity was ensured by means of ultrasound imaging, and anamneses of patients were recorded. We measured the axial in situ stretches, load-free geometries and opening angles. Passive biaxial mechanical responses of preconditioned cylindrical specimens were studied in 37°C calcium-free Tyrode solution under quasistatic loading conditions. Specimens were subjected to pressure cycles varying from 0 to 33.3kPa (250mmHg) at nine fixed axial loads, varying from 0 to 9.90N. For the description of the load-deformation behavior we employed five “two-dimensional” orthotropic strain-energy functions frequently used in arterial wall mechanics. The associated constitutive models were compared in regard to their ability of representing the experimental data. Histology showed that the arteries were of the muscular type. In contrast to animal arteries they exhibited intimal layers of considerable thickness. The average ratio of wall thickness to outer diameter was 7.7, which is much less than observed for common animal arteries. We found a clear correlation between age and the axial in situ stretch λis(r=−0.72,P=0.03), and between age and distensibility of specimens, i.e. aged specimens are less distensible. Axial in situ stretches were clearly smaller (1.07±0.09,mean±SD) than in animal arteries. For one specimen λis was even smaller than 1.0, i.e. the vessel elongated axially upon excision. The nonlinear and anisotropic load-deformation behavior showed small hystereses. For the majority of specimens we observed axial stretches smaller than 1.3 and circumferential stretches smaller than 1.1 for the investigated loading range. Data from in situ inflation tests showed a significant increase of the axial stretch with intraluminal pressure. Thus, for this type of artery the axial in situ stretch of a non-pressurized vessel is not representative of the axial in vivo stretch. None of the constitutive models were able to represent the deformation behavior of the entire loading range. For the physiological loading range, however, some of the models achieved good agreement with the experimental data.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 150 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3