Affiliation:
1. Argonne National Laboratory, Components Technology Division, Argonne, Il. 60439
Abstract
Thermal fluctuations were measured in the tube wall in the transition boiling zone of a full-scale LMFBR sodium-heated steam generator tube. The tube had an inside diameter = 10 mm, wall thickness = 2.90 mm, heated length = 13.1 m, and material = 2 1/4 Cr-1 Mo steel. Water flowed vertically upwards inside the straight tube, and sodium flowed counter-currently in a surrounding annulus. Results of thermal, spectral, and thermal stress analyses are presented for a test within the normal operating range of LMFBR steam generators. Results of other tests are presented that show the effects and sensitivity of sodium temperature and water pressure on the severity of the thermal fluctuations.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Cited by
17 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献