Designing, Modelling and Experimental Investigation of Direct Evaporative Cooling System Coupled With Commercial Desiccant Dehumidifier

Author:

Basit Abdul1,Mahmood Mariam1,Waqas Adeel1,Ali Majid1,Khalid Waqas2

Affiliation:

1. U.S. Pakistan Center for Advanced Studies in Energy (USPCASE)-National University of Sciences and Technology, Islamabad 44000, Pakistan

2. School of Mechanical and Manufacturing Engineering (SMME)-National University of Sciences and Technology, Islamabad, Pakistan

Abstract

Abstract With the increasing demand of clean and energy-efficient air conditioning systems, evaporative air cooling technique is gaining significant attention owing to less energy consumption and environmentally safe technology in comparison with conventional refrigerant-based air conditioners. In this study, commercial desiccant dehumidifier is coupled with experimentally developed direct evaporative cooling (DEC) system to first dehumidify the air and then pass it through DEC to achieve human thermal comfort level defined by ASHRAE standards. Under the climatic conditions of Islamabad, Pakistan, multiple experiments were carried out at different temperatures, flowrate, and relative humidity of air during November, when air temperature and relative humidity were in the range of 25–30 °C and 40–60%, respectively. To analyze the system performance under summer ambient conditions, indoor temperature was increased by 8–10 °C and relative humidity by 15–25% in laboratory. Experimental analysis showed that the system can provide human comfort level for a range of temperature 29–39.7 °C and relative humidity of 65–80% at flowrate of 180 m3/h. To achieve thermal comfort at higher humidity level, DEC is coupled with commercial desiccant dehumidifier. However, due to desiccant regeneration by an electric heater in the dehumidifier, the overall power consumption of the whole system increases up to 1.95 kW. Two well-known indices coefficient of performance (CoP) and energy efficiency ratio (EER) are used to analyze the system performance. Experimental analysis revealed that CoP decreases with the increasing specific humidity of air, decreasing ambient temperature, and flowrate.

Publisher

ASME International

Subject

Fluid Flow and Transfer Processes,General Engineering,Condensed Matter Physics,General Materials Science

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3