A Simplified Algorithm for Count Rate Processing in Radiation Monitors That Address Statistical Fluctuations and Spurious Counts

Author:

Nanda Biswamohan1,Madhavi Voleti2,Suguna Devi S. V.1,Balachandran R.1

Affiliation:

1. Electronics Corporation of India Limited, Instrumentation Section, Control Systems Group, ECIL, ECIL Post, Hyderabad, Telangana 500062, India

2. Bhabha Atomic Research Centre Electronics Division, BARC, Trombay, Mumbai, Maharashtra 400094, India

Abstract

Abstract While processing the signals from radiation detectors, for finding the true mean-count-rate, algorithms with hybrid pulse collection methodology have been proposed and used over the years. An algorithm based on this technique with a new methodology of adoption and implementation including spurious rejection is proposed here. It enables a specified and controllable error when the mean-count-rate remains within certain predefined limits from its true value. Effort is made to optimize the response time of prediction at low count rates preserving the optimum possible relative-standard-deviation (RSD). Chi-squared test is utilized for verifying the counting system to check if the observed fluctuations are consistent with the expected statistical fluctuations. A C-program code has been developed to test the algorithm. An observed set of detector outputs are given as input to the program and the corresponding Output is analyzed. A comparative study between the proposed method and floating-mean method is presented for the same set of observations. A typical short-lived high voltage (HV) induced spurious noise pattern is fed as input to the program verifying limited-spurious rejection capability of the algorithm. An embedded C program was written for microcontroller implementation of the algorithm. Case-study of a neutron roentgen equivalent man (REM) counter is presented for evaluating response time for various ranges of operation with calculation of RSD at these ranges. This general-purpose algorithm can enhance the read-out accuracy of radiation monitors used for radiation safety applications.

Publisher

ASME International

Subject

Nuclear Energy and Engineering,Radiation

Reference8 articles.

1. Microprocessor Implementation of a Time Variant Floating Mean Counting Algorithm;Nucl. Instrum. Methods Phys. Res. Sect. A,1999

2. A Software Method for Suppressing Statistical Fluctuations in Preset Count Digital Rate Meter Algorithms;IEEE Trans. Nucl. Sci.,2002

3. Uncertainty of Measurement—Part 3: Guide to the Expression of Uncertainty in Measurement, (GUM:1995);BIPM,2008

4. Counting Statistics & Error Prediction,1989

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3