Abstract
Energy conservation in data centers with liquid-cooled electronics is considered, taking into account the combined power consumption of both the electronics and the associated cooling equipment, particularly chillers. The energy-saving technique called “free cooling,” which is most effective at minimizing or eliminating the need for chillers when the temperature of the coolant delivered to the electronics is high, is shown to be at odds with the electronics itself, because of subthreshold leakage in complementary metal-oxide semiconductor (CMOS) transistors, which is minimized when coolant temperature is low. A mathematical model is developed to investigate this trade-off, to discover what liquid-coolant temperature is optimal overall, and thereby to determine what combination of free cooling and traditional chiller cooling should be used for minimal overall power consumption. As an example of how to apply the mathematical model, parameters are chosen in accordance with experimental measurements on an early prototype of a state-of-the-art, water-cooled computer (International Business Machines's (IBM) BlueGene/Q). Results for total data-center power (computer + cooling equipment) are obtained as a function of coolant temperature, the computational state of the computer (which affects CMOS leakage), and weather (which affects the ability to employ free cooling). For the type of system considered, the optimal coolant temperature is found to be a discontinuous function of the other parameters, and traditional chiller cooling is found sometimes to be more energy efficient than free cooling.
Subject
Fluid Flow and Transfer Processes,General Engineering,Condensed Matter Physics,General Materials Science
Reference15 articles.
1. U.S. Environmental Protection Agency, 2007, Report to Congress on Server and Data Center Energy Efficiency, Public Law 109-431, Aug. 2.
2. Hanson
, Susanna, and Harshaw, Jeanne, 2008, “Free Cooling Using Water Economizers,” TRANE Engineers Newsletter, Vol. 37-3.
3. Breen, T. J., Walsh, E. J., Punch, J., Shah, A. J., Bash, C. E., Kumari, N., and Cader, T., 2011, “From Chip to Cooling Tower Data Center Modeling: Chip Leakage Power and Its Impact on Cooling Infrastructure Energy Efficiency,” Proceedings of the ASME 2011 Pacific Rim Technical Conference and Exposition on Packaging and Integration of Electornic and Photonic Systems, InterPACK2011, July 6–8.
4. From Chip to Cooling Tower Data Center Modeling (Part 1): Influence of Server Inlet Temperature and Temperature Rise Across Cabinet;J. Electron. Packag.,2011
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献