Development of a Standard Bond Test for Indented Prestressing Wires

Author:

Arnold Matthew L.1,Peterman Robert J.1,Bodapati Naga Narendra B.1,Beck B. Terry1,Wu Chih-Hang (John)1

Affiliation:

1. Kansas State University, Manhattan, KS

Abstract

An experimental testing program was conducted at Kansas State University (KSU) to test the bond characteristics of various 5.32 mm-diameter, Grade 270 low-relaxation steel wires used in prestressed concrete railroad ties. This un-tensioned pullout test could serve as a quality control test similar to the NASP (North American Strand Producers) Strand Bond Test that has been developed for pre-tensioned strands. A total of twelve (12) wires produced by six different steel manufacturers were used to develop the wire pullout test. All of the wires were tested in their “as-received” condition and have different indent geometries. It is generally accepted that indentations in the wire improve the bond between the steel and concrete. However, there are currently no commonly accepted quality control tests that accurately predict a wire’s bond characteristics in a pre-tensioned application. The un-tensioned pullout test developed is comparable to the NASP [Strand] Bond Test. The specimens consist of a 4 in. (100 mm) outer-diameter tube with a total length of 8 in. (200 mm) and a steel plate welded to the bottom. The 5.32 mm-diameter wire was centered in the tube and the sand-cement mortar was placed and allowed to cure. The flow of the mortar was measured for consistency and 2” × 2” (50 mm × 50 mm) mortar cubes were used to determine the compressive strength of the mortar. The specimens were tested when the compressive strength of the mortar was between 4500 and 5000 psi (31.0 MPa and 34.5 MPa). Each batch of mortar contained 12 pullout specimens; one with each wire type. Each wire was tested six times leading to a total of six batches and a total of 72 mortar specimens. During testing, the wires were loaded in force control at the bottom, while continuously monitoring and recording the movement (slip) of the wire with respect to the mortar at the opposite (top) end. The force verses end-slip data of the six tests for each wire type were numerically combined to obtain the average bond performance. These average results from the un-tensioned pullout tests were then compared to transfer length measurements from accompanying pre-tensioned concrete prisms. In general, the wire end slip measurements from the pullout tests were found to have good correlation with the measured transfer length. For all 12 wires, a coefficient of determination (R2) of 0.872 was found between the average pullout force (at 0.10-inch (2.54 mm) of wire free-end slip) and average transfer length measurements from the accompanying concrete prism tests. However, when only the indented wires were considered, the R2 increased to 0.913.

Publisher

American Society of Mechanical Engineers

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3