Affiliation:
1. Lappeenranta University of Technology, Lappeenranta, Finland
Abstract
The supercritical CO2 (sCO2) Brayton cycle has been attracting much attention to produce the electricity power, chiefly due to its higher thermal efficiency with the relatively lower temperature at the turbine inlet compared to other common energy conversion cycles. Centrifugal compressor operating conditions in the supercritical Brayton cycle are commonly set in vicinity of the critical point, owing to smaller compressibility factor and eventually lower compressor work.
This paper investigates and compares different centrifugal compressor design methodologies in close proximity to the critical point and suggests the most accurate design procedure based on the findings. An in-house mean-line design code, which is based on the individual enthalpy loss models, is compared to stage efficiency correlation design methods. Moreover, modifications are introduced to the skin friction loss calculation to establish an accurate 1-D design methodology. Moreover, compressor performances are compared to the experimental measurements.
Publisher
American Society of Mechanical Engineers
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献