Abstract

Due to its extensive application, the safety issue of lithium-ion battery has received increasing attention. For crashworthiness design of battery in electric vehicles, it is of great importance to investigate the response of the battery under mechanical loading and understand the mechanism of internal short circuit. Quasi-static and intermediate strain rate uniaxial tension tests were conducted on the electrodes and the separators. The high speed camera and DIC (digital image correlation) method were adopted to measure the strain while a self-design load cell was used to measure force in dynamic test. Either loading velocity or loading direction was varied in different tests. The upper limit of the test strain rate achieved 66 /sec. All the component materials showed strain rate dependency and separators demonstrated noticeable anisotropy. Quasi-static penetration tests were conducted on two different types of pouch cell using steel and plastic punch heads. For both Type A pouch cell and Type B pouch cell, during penetration process using plastic punch head, no significant voltage drop or temperature rise was observed. During penetration process using steel punch head, only Type A pouch cell produced short circuit. When the punch head was removed, the voltage of the cells could recover to certain level. From post mortem examination, it was found that for a single pouch cell, all the electrodes presented the same fracture mode that the stacked anode and cathode formed several fragments in the penetration path, while the separators in between only formed a central crack when the punch head went through. Since the separators had a larger elongation ratio than the electrodes, the extended separators around the rupture location could block the direct and constant contact between anode and cathode, electrodes and steel punch, which explained why no massive internal short circuit was initiated. The drop tower was used to conduct dynamic penetration test. The results indicated that under dynamic loading, internal short circuit was more likely to be triggered which can be explained by the strain rate effect of the separators. This study highlighted the importance of the separator to the safety performance of pouch cells.

Publisher

American Society of Mechanical Engineers

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3