Numerical Simulations of Heat and Mass Transfer in Condensing Heat Exchangers for Water Recovery in Power Plants

Author:

Jeong Kwangkook1,Bilirgen Harun2,Levy Edward2

Affiliation:

1. Arkansas State University, Jonesboro, AR

2. Lehigh University, Bethlehem, PA

Abstract

Power plants release a large amount of water vapor into the atmosphere through the stack. The flue gas can be a potential source for obtaining much needed cooling water for a power plant. If a power plant could recover and reuse a portion of this moisture, it could reduce its total cooling water intake requirement. One of the most practical way to recover water from flue gas is to use a condensing heat exchanger. The power plant could also recover latent heat due to condensation as well as sensible heat due to lowering the flue gas exit temperature. Additionally, harmful acids released from the stack can be reduced in a condensing heat exchanger by acid condensation. Condensation of vapors in flue gas is a complicated phenomenon since heat and mass transfer of water vapor and various acids simultaneously occur in the presence of non-condensable gases such as nitrogen and oxygen. Design of a condenser depends on the knowledge and understanding of the heat and mass transfer processes. A computer program for numerical simulations of water (H2O) and sulfuric acid (H2SO4) condensation in a flue gas condensing heat exchanger was developed using MATLAB. Governing equations based on mass and energy balances for the system were derived to predict variables such as flue gas exit temperature, cooling water outlet temperature, mole fraction and condensation rates of water and sulfuric acid vapors. The equations were solved using an iterative solution technique with calculations of heat and mass transfer coefficients and physical properties. An experimental study was carried out in order to yield data for validation of modeling results. Parametric studies for both modeling and experiments were performed to investigate the effects of parameters such as flue gas flow rate, cooling water flow rate, inlet cooling water temperature and tube configurations (bare and finned tubes) on condensation efficiency. Predicted results of water and sulfuric acid vapor condensation were compared with experimental data for model validation, and this showed agreement between experimental data and predictions to within a few percent. The most important parameters affecting performance of the condensing heat exchangers was the ratio of cooling water to flue gas flow rates, since this determines how much heat the cooling water can absorb. The computer program simultaneously calculates both water vapor condensation and sulfuric acid condensation in flue gas along downstream. Modeling results for prediction of sulfuric acid vapor concentration in the flue gas were compared with measured data obtained by the controlled condensation method. An analytical model of sulfuric acid condensation for oil-firing showed two trends — steep reduction within the high temperature heat exchanger and smooth reduction within lower temperature heat exchanger, which is in agreement with experimental data.

Publisher

ASMEDC

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司