Affiliation:
1. University of Connecticut
Abstract
A complete numerical analysis of heat pipes is performed with no empirical correlations while including the flow in a wick. The numerical model is validated from experimental and numerical work. Single and multiple heat sources were used as well as constant, convective and radiative heat sinks. The numerical model does not fix the internal pressure references by a point, but allows is to rise and fall based on the physics of the problem. Also, the capillary pressure needed in the wick to drive the flow is obtained for various heating configurations and powers. These capillary pressures, in conjunction with an analysis that predicts the maximum capillary pressure for a given heating load is used to determine the dry-out limitations of a heat pipe.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献