Effect of Rib-Angle Orientation on Local Mass Transfer Distribution in a Three-Pass Rib-Roughened Channel

Author:

Han J. C.1,Zhang P.1

Affiliation:

1. Turbine Heat Transfer Laboratory, Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843

Abstract

In this experimental investigation of the heat transfer characteristics of turbulent air flow in a three-pass square channel, the test section consisted of three straight square channels jointed by two 180 deg turns, modeling the internal cooling passages of gas turbine airfoils. Naphthalene-coated ribs were attached to the top and bottom walls of the naphthalene-coated, three-pass channel. The rib height-to-hydraulic diameter ratio was 0.063; the rib pitch-to-height ratio was 10; the rib angles were 90 and 60 deg. For α = 60 deg, both the crossed ribs (on two opposite walls of the cooling channel) and the parallel ribs (on two opposite walls of the cooling channel) were investigated. The combined effects of the two sharp 180 deg turns and the rib orientations on the distributions of the local mass transfer coefficient in the entire three-pass channel were determined. The rib angle, the rib orientation, and the sharp 180 deg turn significantly affect the local mass transfer distributions. The combined effects of these parameters can increase or decrease the mass transfer coefficients after the sharp 180 deg turns. The angled ribs, in general, provide higher mass transfer coefficients than the transverse ribs; the parallel ribs give higher mass transfer than the crossed ribs.

Publisher

ASME International

Subject

Mechanical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3