Viscoelastic Stress Analysis of Constrained Proton Exchange Membranes Under Humidity Cycling

Author:

Lai Yeh-Hung1,Mittelsteadt Cortney K.2,Gittleman Craig S.1,Dillard David A.3

Affiliation:

1. Fuel Cell Research Lab, General Motors Corporation, Honeoye Falls, NY 14472-0603

2. Giner Electrochemical Systems, LLC, Newton, MA 02466

3. Engineering Science and Mechanics Department, Virginia Tech, Blacksburg, VA 24061

Abstract

Many premature failures in proton exchange membrane (PEM) fuel cells are attributed to crossover of the reactant gas from microcracks in the membranes. The formation of these microcracks is believed to result from chemical and/or mechanical degradation of the constrained membrane during fuel cell operation. By characterizing the through-membrane leakage, we report failures resulting from crack formation in several PEMs mounted in 50cm2 fuel cell fixtures and mechanically stressed as the environment was cycled between wet and dry conditions in the absence of chemical potential. The humidity cycling tests also show that the failure from crossover leaks is delayed if membranes are subjected to smaller humidity swings. To understand the mechanical response of PEMs constrained by bipolar plates and subjected to changing humidity levels, we use Nafion® NR-111 as a model membrane and conduct numerical stress analyses to simulate the humidity cycling test. We also report the measurement of material properties required for the stress analysis—water content, coefficient of hygral expansion, and creep compliance. From the creep test results, we have found that the principle of time-temperature-humidity superposition can be applied to Nafion® NR-111 to construct a creep compliance master curve by shifting individual compliance curves with respect to temperature and water content. The stress prediction obtained using the commercial finite element program ABAQUS® agrees well with the stress measurement of Nafion® NR-111 from both tensile and relaxation tests for strains up to 8%. The stress analysis used to model the humidity cycling test shows that the membrane can develop significant residual tensile stress after humidity cycling. The result shows that the larger the humidity swing and/or the faster the hydration/dehydration rate, the higher the residual tensile stress. This result is confirmed experimentally as PEM failure is significantly delayed by decreasing the magnitude of the relative humidity cycle. Based on the current study, we also discuss potential improvements for material characterization, material state diagnostics, and a stress model for PEMs.

Publisher

ASME International

Subject

Mechanical Engineering,Mechanics of Materials,Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electronic, Optical and Magnetic Materials

Reference47 articles.

1. DuPont, 2008, Product Information Sheets, http://www.dupont.com/fuelcells/pdf/extrusion_cast.pdf.

2. Uan-Zo Li, J. T. , 2001, “The Effects of Structure, Humidity and Aging on the Mechanical Properties of Polymeric Ionomers for Fuel Cell Applications,” MS thesis, Virginia Polytechnic Institute and State University, Blacksburg, VA.

Cited by 116 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3