A Proposed Method and Case Study of Waste Heat Recovery in an Industrial Application

Author:

Wechs Nikolaus1,Floss Alexander G.1,Tiller Dale K.2

Affiliation:

1. Biberach University of Applied Sciences, Karlstrasse 11, Biberach 88400, Germany

2. University Nebraska Lincoln, 1110 S 67th St, Omaha, NE 68182

Abstract

Abstract Waste heat recovered from a refrigeration machine is associated with the double benefit of generating cold and heat with just one unit. Additional energy is required in most cases to achieve these benefits. To evaluate the efficiency of waste heat recovery, two novel efficiency indicators are described. The overhead coefficient of performance (OCOP) describes additional electrical power required to raise the temperature to make waste heat usable. The coefficient of savings describes power reduction when condenser heat is fed into a cold district heating network instead of exhausting it to high-temperature outside air. Results are reported from a case study in a food logistic center with high cooling demand in Isny, Germany. Waste heat at this facility was previously released unused to outside air. We describe how this waste heat can be used to supply sustainable heat supply to a new residential area. During the design phase, it is difficult to choose the best operating temperature for district heating networks (DHNs). The novel indicators are used to value the effort to make waste heat usable. Whereas a supply temperature of 20 °C has no disadvantages for the operator, a supply temperature of 40 °C is associated with an increase in electricity consumption. The resulting OCOPs are above 5.0 even under unfavorable conditions and exceed the theoretically calculated (Holm and Pehnt, 2023, Wärmeschutz und Wärmepumpe-Warum Beides Zusammengehört, Forschungsinstitut für Wärmeschutz e.V., Institut für Energie und Umweltforschung, München/Berlin/Heidelberg, p, 13, 14; Agora Energiewende, Fraunhofer IEG, 2023, Roll-out von Großwärmepumpen in Deutschland, Strategien für den Markthochlauf in Wärmenetzen und Industrie, Berlin) and measured (Fraunhofer Institut für Solare Energiesysteme, 2020, “Wärmepumpen in Bestandsgebäuden, Ergebnisse aus dem Forschungsprojekt, WP-Smart im Bestand.”) coefficients of performance (COPs) for air-sourced heat pumps. Although using waste heat is not free, it is beneficial when overall efficiency is considered.

Publisher

ASME International

Reference21 articles.

1. Wege zu Einem Klimaneutralen Energiesystem;Brandes,2021

2. Integrating Low-Temperature Renewables in District Energy Systems: Guidelines for Policy Makers;IRENA and Aalborg University,2021

3. Energetische Optimierung der Fernwärme Ulm;Zepf,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3