Effect of Endwall Contouring on a Transonic Turbine Blade Passage: Heat Transfer Performance

Author:

Panchal Kapil V.1,Abraham Santosh2,Roy Arnab3,Ekkad Srinath V.4,Ng Wing5,Lohaus Andrew S.6,Crawford Michael E.7

Affiliation:

1. Elliott Group, 901 North Fourth Street, CB200, Jeannette, PA 15644 e-mail:

2. Siemens Energy, Inc., 5101 Westinghouse Boulevard, Charlotte, NC 28273-9640 e-mail:

3. Department of Mechanical Engineering, Virginia Tech, Blacksburg, VA 24061 e-mail:

4. Department of Mechanical Engineering, 301 Burruss Hall, 800 Drillfield Drive, Blacksburg, VA 24061 e-mail:

5. Department of Mechanical Engineering, Virginia Tech, 425 Goodwin Hall (0238), 635 Prices Fork Road, Blacksburg, VA 24061 e-mail:

6. Siemens Energy, Inc., 4400 Alafaya Trail, Orlando, FL 32789 e-mail:

7. Siemens Energy, Inc., 11842 Corporate Boulevard, Orlando, FL 32817 e-mail:

Abstract

Effect of turbine endwall contouring on its aerodynamic performance has been widely studied, but only a few studies are available in the open literature investigating its effect on heat transfer performance; especially at transonic exit Mach number conditions. In this paper, we report a study of effect of contouring on endwall heat transfer performance of a high-turning high-pressure (HP) turbine blade passage operating under transonic exit conditions. The paper describes comparison of heat transfer performance of two contoured endwall geometries, one aerodynamically optimized (AO) and the other heat transfer optimized (HTO), with a baseline, noncontoured geometry. The endwall geometries were experimentally investigated at Virginia Tech's transient, blow down, transonic linear cascade facility at three exit Mach numbers, Mex= 0.71, 0.88(design) and 0.95, for their heat transfer performance. Endwall surface temperatures were measured using infrared (IR) thermography and local heat transfer coefficient (HTC) values were calculated using measured temperatures. A camera matrix model-based data postprocessing technique was developed to relate the two-dimensional images captured by IR camera to three-dimensional endwall contours. The measurement technique and the methodology for postprocessing of the heat transfer coefficient data have been presented in detail. Discussion and interpretation of experimental results have been augmented using aerodynamic CFD simulations of the geometries. Both the contoured endwalls demonstrated a significant reduction in the overall average heat transfer coefficient values of the order of 10%. The surface Stanton number distributions also indicated a reduction in the level of hot spots for most of the endwall surface. However, at some locations an increase was also observed, especially in the area near the leading edge (LE). The results indicate that the endwall contouring could significantly improve heat transfer performance of turbine passages.

Publisher

ASME International

Subject

Mechanical Engineering

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3