Advancement of Reactor Coolant Pump (RCP) Performance Verification Test in KAERI

Author:

Cho Yun-Je1,Kim Yeon-Sik1,Cho Seok1,Kim Seok1,Bae Byoung-Uhn1,Chung Heung-June1,Youn Young-Jung1,Park Jong-Kuk1,Choi Hae-Seob1,Jeon Woo-Jin1,Kim Bok-Deuk1,Kwon Tae-Soon1,Song Chul-Hwa1

Affiliation:

1. KAERI, Daejeon, South Korea

Abstract

Korea Atomic Energy Research Institute (KAERI) has designed and constructed a test facility for reactor coolant pumps (RCPs). The RCP Test Facility (RCPTF) has the capability to test a RCP under the operation condition of an Advanced Power Reactor 1400 MW (APR1400). The design values of the facility are 17.2 MPa, 343 °C, 11.7 m3/s, and 13 MW in maximum pressure, temperature, flow rate, and electrical power, respectively. In the facility, it is possible to perform a type test for a newly-developed RCP as well as a production test for a RCP before its installation in a nuclear power plant. For the production test, H-Q curves under the cold and hot conditions are acquired. For the type test, various transient tests are additionally performed including four types of seal transient tests, a thrust bearing transient test, a cost down test, and so on. To acquire H-Q curves of a RCP, the flow rate should be controlled by varying the flow resistance in the test loop. The RCPTF uses a Variable Restriction Orifice (VRO) whose flow area can be controlled by moving the two orifice plates installed in-parallel. The need for flow control valves and bypass lines was eliminated using the VRO such that the flow disturbance was minimized. The flow rate in the main loop of the RCPTF is measured by a standard venture flow meter. The flow rate in the RCPTF is very high and thus the venture flow meter could not be calibrated in the entire range of Reynolds number corresponding to the operating condition in the APR1400. The calibration was conducted at the Colorado Experiment Engineering Station Inc. (CEESI) in the USA where natural gas is used for a working fluid. If a discharge coefficient calibrated with the gas is applied in the test results performed using the water as a working fluid, a discrepancy can occur due to the static hole error. Therefore, the static hole error was compensated in the test results and the result shows the improvement. The effect of the temperature on the pressure pulsation amplitude was also evaluated. During a cold performance test and heat-up phase to the condition of a hot performance test, an abnormal increase in the pressure pulsation amplitude was observed near the specific temperature range. This is acoustic resonance phenomena that occur when a blade passing frequency of the RCP is proportional to the harmonic resonance frequency of the RCPTF.

Publisher

American Society of Mechanical Engineers

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3