Affiliation:
1. Department of Mechanical and Materials Engineering, Queen's University, Kingston, ON K7L 3N6, Canada e-mail:
Abstract
Short annular diffusers with negative wall angles were evaluated numerically and experimentally with up to 40 deg inlet swirl at an inlet Reynolds number of Ret ≈ 1.4 × 105 and Mach number of Mt ≈ 0.16. The 80% experimental effectiveness of the 1.61 and 1.91 area ratio (AR) diffusers with 0–20 deg inlet swirl were on par with unswirled maximums reported in literature and computational fluid dynamics (CFD) predicted reasonable outlet axial velocity profiles and wall pressure distributions. The AR = 2.73 diffuser's effectiveness without swirl was 13% below the maximum for the given AR and larger discrepancies occurred in the CFD results due to the incorrect prediction of the recirculation zone strength. Preference was given to the realizable k–ε model on coarse grids with wall functions that predicted performance of all cases with at least 20 deg inlet swirl to within 20%.
Subject
Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering
Reference37 articles.
1. Experimentally Determined Optimum Geometries for Rectilinear Diffusers With Rectangular, Conical, or Annular Cross-Section,1967
2. The Effect of Inlet Conditions on the Flow in Annular Diffusers,1953
3. Stevens, S. J., 1967, “The Performance of Annular Diffusers,” Proc. Inst. Mech. Eng., 182(4), pp. 58–70.10.1243/PIME_CONF_1967_182_130_02
4. Performance and Flow Regimes for Annular Diffusers;ASME,1967