Affiliation:
1. University of Missouri at Kansas City, Kansas City, MO
Abstract
This paper provides information on swing check valve selection criteria suitable for nuclear power plant applications. In this project, four swing check valves were analyzed to demonstrate the implementation and application of this information. In this example, swing check valves were selected according to “ASME Boiler and Pressure Vessel Code, Section III” [1] and “ASME B16.34, Valves Flanged, Threaded, and Welding End” [2]. This paper also discusses the utilization of Computational Fluid Dynamics Software (CFD) as a means to analyze valve design. The use of CFD is a relatively new approach for validation of valve design that is becoming invaluable due to the high cost of physical bench testing. The Instrument Society of America (ISA) Analysis Division and the American Society of Mechanical Engineers (ASME) Computational Fluid Dynamics Technical Committee have taken a proactive approach in setting standards and practices for the use of CFD in design and validation.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献