The Effect of Inhomogeneous Trabecular Stiffness Relationship Selection on Finite Element Outcomes for Shoulder Arthroplasty

Author:

Reeves Jacob M.1,Athwal George S.2,Johnson James A.1,Langohr G. Daniel G.1

Affiliation:

1. Department of Mechanical Engineering, Western University Canada, 1151 Richmond Street, London, ON N6A3K7, Canada e-mail:

2. Roth|McFarlane Hand and Upper Limb Centre, 268 Grosvenor StreetE-p, London, ON N6A4V2, Canada e-mail:

Abstract

An important feature of humeral orthopedic finite element (FE) models is the trabecular stiffness relationship. These relationships depend on the anatomic site from which they are derived; but have not been developed for the humerus. As a consequence, humeral FE modeling relies on relationships for other anatomic sites. The variation in humeral FE outcomes due to the trabecular stiffness relationship is assessed. Stemless arthroplasty FE models were constructed from CT scans of eight humeri. Models were loaded corresponding to 45 deg and 75 deg abduction. Each bone was modeled five times with the only variable being the trabecular stiffness relationship: four derived from different anatomic-sites and one pooled across sites. The FE outcome measures assessed were implant-bone contact percentage, von Mises of the change in stress, and bone response potential. The variance attributed to the selection of the trabecular stiffness relationship was quantified as the standard deviation existing between models of different trabecular stiffness. Overall, variability due to changing the trabecular stiffness relationship was low for all humeral FE outcome measures assessed. The variability was highest within the stress and bone formation potential outcome measures of the trabecular region. Variability only exceeded 10% in the trabecular stress change within two of the eight slices evaluated. In conclusion, the low variations attributable to the selection of a trabecular stiffness relationship based on anatomic-site suggest that FE models constructed for shoulder arthroplasty can utilize an inhomogeneous site-pooled trabecular relationship without inducing marked variability in the assessed outcome measures.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3