Abstract
Nonintrusive, spatially resolved instantaneous temperature measurements are presented that were obtained from a reacting spray flame in a model gas turbine can combustor using coherent anti-Stokes Raman scattering (CARS) thermometry. The results show that CARS measurements agree with thermocouple measurements at the exit of the combustor. The liquid droplet induced dielectric breakdown is not an obstacle in applying CARS to reacting sprays. The CARS measured temperature field also indicates that there is a relatively cool region (T < 1000 K) near the nozzle tip. Reaction occurs in the region where large numbers of droplets are present and in the interface of the swirl-induced recirculation zone. This study demonstrates that CARS is a viable diagnostic tool for nonintrusive, instantaneous temperature measurements in practical spray flames.
Subject
Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献