A Uniaxial Testing Approach for Consistent Failure in Vascular Tissues

Author:

Sang Chao1,Maiti Spandan2,Fortunato Ronald N.1,Kofler Julia3,Robertson Anne M.4

Affiliation:

1. Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 636 Benedum Hall 3700 O'Hara Street, Pittsburgh, PA 15261 e-mail:

2. Department of Bioengineering, University of Pittsburgh, 302 Benedum Hall 3700 O'Hara Street, Pittsburgh, PA 15261 e-mail:

3. Department of Pathology, University of Pittsburgh, S701.3 Scaife Hall, Pittsburgh, PA 15261 e-mail:

4. Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 440 Benedum Hall 3700 O'Hara Street, Pittsburgh, PA 15261 e-mail:

Abstract

Although uniaxial tensile testing is commonly used to evaluate failure properties of vascular tissue, there is no established protocol for specimen shape or gripping method. Large percentages of specimens are reported to fail near the clamp and can potentially confound the studies, or, if discarded will result in sample waste. The objective of this study is to identify sample geometry and clamping conditions that can achieve consistent failure in the midregion of small arterial specimens, even for vessels from older individuals. Failure location was assessed in 17 dogbone specimens from human cerebral and sheep carotid arteries using soft inserts. For comparison with commonly used protocols, an additional 22 rectangular samples were tested using either sandpaper or foam tape inserts. Midsample failure was achieved in 94% of the dogbone specimens, while only 14% of the rectangular samples failed in the midregion, the other 86% failing close to the clamps. Additionally, we found midregion failure was more likely to be abrupt, caused by cracking or necking. In contrast, clamp failure was more likely to be gradual and included a delamination mode not seen in midregion failure. Hence, this work provides an approach that can be used to obtain consistent midspecimen failure, avoiding confounding clamp-related artifacts. Furthermore, with consistent midregion failure, studies can be designed to image the failure process in small vascular samples providing valuable quantitative information about changes to collagen and elastin structure during the failure process.

Funder

National Institute of Neurological Disorders and Stroke

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference48 articles.