Nonhomogeneous Strain From Sparse Marker Arrays for Analysis of Transmural Myocardial Mechanics

Author:

Kindberg K.1,Karlsson M.1,Ingels N. B.2,Criscione J. C.3

Affiliation:

1. Division of Biomedical Modelling and Simulation, Department of Biomedical Engineering, Linköpings Universitet, SE–581 85, Linköping, Sweden

2. Department of Cardiothoracic Surgery, School of Medicine, Stanford University, Stanford, CA 94305, and Laboratory of Cardiovascular Physiology and Biophysics, Research Institute of the Palo Alto Medical Foundation, Palo Alto, CA 94305

3. Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843

Abstract

Abstract Background: Knowledge of normal cardiac kinematics is important when attempting to understand the mechanisms that impair the contractile function of the heart during disease. The complex kinematics of the heart can be studied by inserting radiopaque markers in the cardiac wall and study the pumping heart with biplane cineradiography. In order to study the local strain, the bead array was developed where small radiopaque beads are inserted along three columns transmurally in the left ventricle. Method: This paper suggests a straightforward method for strain computation, based on polynomial least-squares fitting and tailored for combined marker and bead array analyses. Results: This polynomial method gives small errors for a realistic bead array on an analytical test case. The method delivers an explicit expression of the Lagrangian strain tensor as a polynomial function of the coordinates of material points in the reference configuration. The method suggested in this paper is validated with analytical strains on a deforming cylinder resembling the heart, compared to a previously suggested finite element method, and applied to in vivo ovine data. The errors in the estimated strain components are shown to remain unchanged on an analytical test case when evaluating the effects of one missing bead. In conclusion, the proposed strain computation method is accurate and robust, with errors smaller or comparable to the current gold standard when applied on an analytical test case.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3