Affiliation:
1. Orthopaedics Bioengineering Laboratory, San Diego Veteran’s Administration Medical Center, Malcolm and Dorothy Coutts Institute for Joint Reconstruction and Research, and University of California, San Diego, Calif.
Abstract
The temperature dependent tensile behavior of ligament was investigated from 2°C to 37°C. Nondestructive cyclic tests were performed on ten canine femur-medial collateral ligament-tibia (FMT) complexes at sequential temperatures of 22°C, 22°C, 27°C, 32°C, 37°C, and again at 22°C. The samples were rested at zero load between tests for sufficient time periods to allow for full recovery from the ligament’s time and history dependent viscoelastic properties. Ten additional FMT complexes were sequentially tested in a similar fashion, but at temperatures of 22°C, 22°C, 2°C, 6°C, 14°C, and 22°C. All canine FMT complexes showed temperature dependent viscoelastic properties: the measured area of hysteresis decreased with increasing temperature; the cyclic load relaxation behavior plateaued to a higher value at lower temperatures; and the tensile load at a predetermined ligament substance strain level had an inversely proportional relationship with respect to temperature.
Subject
Physiology (medical),Biomedical Engineering
Cited by
77 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献