Control of Circumferential Wall Stress and Luminal Shear Stress Within Intact Vascular Segments Perfused Ex Vivo

Author:

El-Kurdi Mohammed S.1,Vipperman Jeffrey S.2,Vorp David A.1

Affiliation:

1. Department of Surgery, Department of Bioengineering, McGowan Institute for Regenerative Medicine, The Center for Vascular Remodeling and Regeneration, University of Pittsburgh, Pittsburgh, PA 15219

2. Department of Mechanical Engineering and Material Science, Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15219

Abstract

Proportional, integral, and derivative (PID) controllers have proven to be robust in controlling many applications, and remain the most widely used control system architecture. The purpose of this work was to use this architecture for designing and tuning two PID controllers. The first was used to control the physiologic arterial circumferential wall stress (CWS) and the second to control the physiologic arterial shear stress (SS) imposed on intact vascular segments that were implanted into an ex vivo vascular perfusion system (EVPS). In order to most accurately control the stresses imposed onto vascular segments perfused ex vivo, analytical models were derived to calculate the CWS and SS. The mid-vein-wall CWS was calculated using the classical Lamé solution for thick-walled cylinders in combination with the intraluminal pressure and outer diameter measurements. Similarly, the SS was calculated using the Hagen–Poiseuille equation in combination with the flow rate and outer diameter measurements. Performance of each controller was assessed by calculating the root mean square of the error (RMSE) between the desired and measured process variables. The performance experiments were repeated ten times (N=10) and an average RMSE was reported for each controller. RMSE standard deviations were calculated to demonstrate the reproducibility of the results. Sterile methods were utilized for making blood gas and temperature measurements in order to maintain physiologic levels within the EVPS. Physiologic blood gases (pH, pO2, and pCO2) and temperature within the EVPS were very stable and controlled manually. Blood gas and temperature levels were recorded hourly for several (N=9)24h perfusion experiments. RMSE values for CWS control (0.427±0.027KPa) indicated that the system was able to generate a physiologic CWS wave form within 0.5% error of the peak desired CWS over each cardiac cycle. RMSE values for SS control (0.005±0.0007dynes∕cm2) indicated that the system was able to generate a physiologic SS wave form within 0.3% error of the peak desired SS over each cardiac cycle. Physiologic pH, pO2, pCO2, and temperature levels were precisely maintained within the EVPS. The built-in capabilities and overall performance of the EVPS described in this study provide us with a novel tool for measuring molecular responses of intact vascular segments exposed to precisely simulated arterial biomechanical conditions.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference22 articles.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3